SAVE VSR 150B INSTALLATIONV01 20210316
Table Of Contents
6
| Prerequisites for Installation
5 Prerequisites for Installation
To ensure a proper and fail-free operation, it is important that the unit is installed according to these instructions.
The unit can be installed in the following positions.
Fig. 3 Possible installation positions
A. Ceiling installation. Left and right connections are possible.
The enclosed mounting brackets are to be used.
B. Horizontal wall installation with the supply air
upwards is allowed.
A wall mounting kit is required. Not delivered with the unit.
C. Vertical wall installation with the supply air
upwards is allowed.
A wall mounting kit is required. Not delivered with the unit.
D. Vertical wall installation position D with the supply air
downwards is not allowed due to the fact that the
heat from the re-heater is rising in the unit.
E. Upside down installation is NOT allowed.
F. Installation on the floor is not allowed.
5.1 Location and Space Requirements
The SAVE VSR 150/B should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.).
Note:
SAVE VSR 150/B must be installed in a heated
area.
When choosing the location it should be kept in mind that
the unit requires maintenance regularly and that the in-
spection door should be easily accessible. Leave free
space for opening the door and for taking out the main
components.
254288 | v01