EDM SYSHP MINI DCI

85
7.11 HOLIDAY AWAY SETTING Menu
MENU > FOR SERVICEMAN > HOLIDAY AWAY SETTING
The HOLIDAY AWAY SETTING menu sengs are used to set the outlet water
temperature to prevent water pipes freezing when away from home in cold weather
seasons. In HOLIDAY AWAY SETTING the following parameters should be set.
T1S_H.A._H sets the heat pump’s leaving water set temperature for space heang
mode when in holiday away mode.
T5S_H.M_DHW sets the heat pump’s leaving water set temperature for DHW mode
when in holiday away mode.
Figure 3-7.35: HOLIDAY AWAY SETTING menu
7.12 SERVICE CALL Menu
MENU > FOR SERVICEMAN > SERVICE CALL
In SERVICE CALL the following parameters can be set.
PHONE NO. and MOBILE NO. can be used to set aer-sales service contact numbers.
If set, these numbers are displayed to users in MENU > SERVICE INFORMATION.
Use to adjust the numerical values. The maximum length of the phone
numbers is 13 digits.
RESTORE FACTORY SETTINGS is used to restore all the
parameters set in the user interface to their factory
defaults.
On selecng YES, the process of restoring all sengs to
their factory defaults begins and progress is displayed as
a percentage.
Figure 3-7.36: SERVICE CALL menu
The black rectangle found between 0 and 9 when scrolling up and down using is converted to a blank space when
the phone numbers are displayed to users in MENU > SERVICE INFORMATION and can be used for phone numbers less
than 13 digits in length.
7.13 RESTORE FACTORY SETTINGS
MENU > FOR SERVICEMAN > RESTORE FACTORY SETTINGS
7.14 TEST RUN
7.14.1 TEST RUN MENU OVERVIEW
MENU > FOR SERVICEMAN > TEST RUN
TEST RUN is used to check that the valves, air purge funcon, circulaon pump, space cooling mode, space heang mode and
DHW mode are all operang correctly.
Figure 3-7.37: RESTORE FACTORY SETTINGS screens