7.3 FOR SERVICEMAN Menu
FOR SERVICEMAN allows installers to input the system conguraon and
set the system parameters. To enter FOR SERVICEMAN, go to MENU > FOR
SERVICEMAN.
Enter the password, using ◄ ► to navigate between digits and using ▼ ▲ to
adjust the numerical values, and then press OK. The password is 234. Refer to
Figure 3-7.2.
7.4 DHW MODE SETTING Menu
7.4.1 DHW MODE SETTING menu overview
MENU > FOR SERVICEMAN > DHW MODE SETTING
In DHW MODE SETTING the following parameters should be set.
DHW MODE enables or disables DHW mode. For installaons with DHW tanks,
select YES to enable DHW mode. For installaons without DHW tanks, select
NON to disable DHW mode. TANK HEATER sets whether or not the domesc hot
water tank has an immersion heater and, if it does, whether or not it is to be
controlled by the Mini Heat Pump Monobloc unit. If the DHW tank does not have
an immersion heater, select NON. If the tank has a heater and it is to be controlled
by the Mini Heat Pump Monobloc unit, select YES. If the tank has a heater but it is
not to be controlled by the Mini Heat Pump Monobloc unit, select NON.
Figure 3-7.2: FOR SERVICEMAN password screen
Figure 3-7.4: DHW MODE SETTING menu
1
Notes:
1. When NON is chosen for 1.1 DHW MODE, only
menu item 1.1 DHW MODE is displayed and
menu items 1.2 to 1.5 are hidden.
Note: If YES is selected, the Mini Heat Pump Monobloc unit’s backup electric heater (if installed) is not used in DHW
mode.
DISINFECT sets whether or not the disinfecon operaon is performed.
DHW PRIORITY sets whether domesc hot water heang or space heang takes priority. If NON is selected in the DHW
PRIORITY mode, when it is available and the space heang/cooling is OFF, the heat pump will heat the water as required.
If space heang/cooling is ON, the water will be heated as required only when the immersion heater is available.
DHW PUMP sets whether or not the DHW pump is controlled by the Mini Heat Pump Monobloc unit. If the DHW pump is to
be controlled by the Mini Heat Pump Monobloc unit, select YES. If the DHW pump is not to be controlled by the Mini Heat
Pump Monobloc unit, select NON.
Figure 3-7.2: FOR SERVICEMAN password screen