L BAL E230
Table Of Contents
- 4.1 General notes
- 4.2 Outdoor installation
- 3.3 Transport
- 6.1 Mode and signal input
- 6 Select operation mode
- 5.11 Potential at control voltage conne
- 5.10 USB–interface
- 5.9.1 Addressing member MODBUS Master I
- 2.4 Requirements placed on the personne
- 2.3 Product safety
- 2.5 Start–up and during operation
- 2.6 Work on the device
- 2.7 Modifications / interventions in th
- 2.8 Operator’s obligation of diligence
- 2.9 Employment of external personnel
- 3 Product overview
- 3.1 Operational area
- 3.2 Maintenance
- 5.8 Relay outputs
- 3.4 Storage
- 3.5 Disposal / recycling
- 4 Mounting
- 5.2 EMC–compatible installation of cont
- 5.9 RS–485 interfaces for MODBUS RTU
- 4.3 Installation location for agricultu
- 4.4 Temperature influences during commi
- 5 Electrical installation
- 5.1 Safety precautions
- 5.3 Mains connection
- 5.4 Signal input or sensor connection (
- 5.5 Control outputs 0 – 10V (A1, A2)
- 5.6 Voltage supply for external devices
- 5.7 Digital inputs (D1, D2)
- 1 General notes
- 2 Safety instructions
- 3 Product overview
- 4 Mounting
- 5 Electrical installation
- 5.1 Safety precautions
- 5.2 EMC–compatible installation of control lines
- 5.3 Mains connection
- 5.4 Signal input or sensor connection (E1, E2)
- 5.5 Control outputs 0 – 10V (A1, A2)
- 5.6 Voltage supply for external devices (+, GND)
- 5.7 Digital inputs (D1, D2)
- 5.8 Relay outputs
- 5.9 RS–485 interfaces for MODBUS RTU
- 5.10 USB–interface
- 5.11 Potential at control voltage connections
- 6 Select operation mode
- 7 Start–up
- 8 Controls and Menu
- 9 Programming
- 9.1 Speed controller
- 9.2 Temperature control
- 9.3 Pressure control for condensers refrigeration
- 9.4 Pressure control airconditioning
- 9.5 Volume control
- 9.6 Air velocity control
- 9.7 Menu group Start
- 9.8 Menu group Info
- 9.9 Controller Setup
- 9.9.1 PIN protection
- 9.9.2 PIN protection
- 9.9.3 user settings
- 9.9.4 Sensor Alarm ON / OFF
- 9.9.5 Limit
- 9.9.6 Minimum speed cut off
- 9.9.7 Reverse action of the control function
- 9.9.8 Controller configuration
- 9.9.9 Group control
- 9.9.10 Display text for external message
- 9.9.11 Offset control signal
- 9.9.12 Selection amplifier (comparator) control circuit 1 or 2 at output A1
- 9.9.13 Data on the total control deviation
- 9.10 IO Setup
- 9.10.1 Analog outputs
- 9.10.2 Digital inputs
- 9.10.2.1 Menu overview
- 9.10.2.2 Enable
- 9.10.2.3 External message, Function
- 9.10.2.4 Limit ON / OFF, Function
- 9.10.2.5 Switch over input
- 9.10.2.6 Output control circuit 2 additional to
- 9.10.2.7 Set 1/2 or Setpoint 1/2, Function
- 9.10.2.8 Intern / Extern Function
- 9.10.2.9 Automatic control / speed manual Function
- 9.10.2.10 Reverse action of control function (
- 9.10.2.11 Switch over Setpoint 1/2 for control circuit 2
- 9.10.2.12 Setting Max. Speed ON / OFF function
- 9.10.2.13 Switch over Setpoint 1/2 and Pband 1/ 2 for control circuit 1
- 9.10.2.14 Switch over Setpoint 1/2 and Pband 1/2 for control circuit 2
- 9.10.2.15 Timer function overwrite
- 9.10.3 Configuration of analog inputs
- 9.10.4 Function and inverting for relay outputs
- 9.10.5 COM2
- 9.11 Limits
- 9.12 Timer
- 9.13 MODBUS Slave
- 9.14 MODBUS Master
- 9.15 Member MOBUS Master
- 10 Menu tables
- 10
- 11 Diagnostics menu
- 12 Protocol
- 13 Enclosure
10 Menu tables
10.1 Menues of operating modes
Mode
1.01
1.02
2.01
2.03
2.04
2.02 2.05
3.01
3.02
3.03
3.04
4.01
4.02
4.03
5.01
5.02
6.01
User Setting
Parameter
Factory setting
Info
Setting direct
1.02 =
80 %
Setting step
1
1.02 = 0
E1-E2 actual
-2.4 °C
Control value
2.04 =
30.0 °C
12.0 bar
22.6 °C
E1 Actual
30.0 °C 30.0 °C 30.0 °C
10.0 bar
-88.7 °C
10.0 bar
-88.7 °C
88.7 Pa 712 m
3
h 0.45 m/s
E2 Actual
- - - - -
2.04 =
30.0 °C
- - - - - 30.0 °C - - - - -
10.0 bar
-88.7 °C
- - - - -
4.02,
4.03 =
21.0 °C
- - - - -
5.02 =
21.0 °C
- - - - -
Setpoint1
1.Setpoint 1
2
20.0 °C 5.0 °C 0.0 °C
12.0 bar
35.0°C
12.0 bar
35.0°C
100 Pa 530 m
3
h 0.50 m/s
2.Setpoint 1
3
Setpoint control
4.02,
4.03 =
100 Pa
5.02 =
530 m
3
h
Modulation
1. Control
2
1.01 =
0 %
0 % 0 % 0 % 0 % 0 % 0 % 0 % 0 %
1. Control
3
0 % 0 %
0 % 0 % 0 % 0 % 0 %
Set external1
1.01 =
0 %
Min. speed cut off
1. Min. speed cut
off
2
OFF OFF OFF OFF OFF OFF OFF OFF
2. Min. speed cut
off
3
Start
PIN input - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Language GB GB GB GB GB GB GB GB GB
US units OFF OFF OFF OFF OFF OFF OFF OFF OFF
Reset OFF OFF OFF OFF OFF OFF OFF OFF OFF
Mode
1.01
1.02
2.01
2.03
2.04
2.02 2.05
3.01
3.02
3.03
3.04
4.01
4.02
4.03
5.01
5.02
6.01
xxx 9.31 9.31 9.31 9.31 9.31 9.31 9.31 9.31 9.31
SN:
000005-
E45536
000005-
E45536
000005-
E45536
000005-
E45536
000005-
E45536
000005-
E45536
000005-
E45536
000005-
E45536
000005-
E45536
Setting
Set Intern1
1.01 =
80%
Set Intern2
1.01 = - -
- - -
Setting direct
1.02 =
80%
Operating Instructions CXE/AVC MODBUS Menu tables
L-BAL-E230-GB 1546 Index 003 Part.-No.
91/112