Protected line and air condenser regulator
Consisting in an electrical line protected from overload and
short-circuits and a FSC, single-phase fan speed control,
with phase cutting regulation for air condenser fan regula-
tion to maintain a constant condensing temperature, or EC
fan speed control by 0-10 signal.
Valid for units with direct expansion circuit only.
Plate water condenser
Consisting in a galvanised steel plate water condenser
sized for water supplied from a dry-cooler or another ex-
ternal water font.
Two-Way water ow adjustment pressure controlled valve.
Consisting in a two-way ball valve for constant condensing
control by 0-10V signal from microprocessor, and a water
condenser installed.
Valid for units with direct expansion circuit only.
Extremely low external temperature kit
Consisting in a LAC valve, in addition to a non-return valve
installed on discharge pipe and an oversize liquid receiver
(already included in the standard delivery) for units to be
installed in extremely cold climates.
Valid for units with direct expansion circuit only.
Technical and testing documentation
The unit are supplied with the technical documentation re-
quired by current international reference regulations regard-
ing correct construction and production of the unit, such as:
complete wiring diagram, declaration of conformity.
Technical manuals enclosed in an USB pen drive.
Unit testing
The units are provided after having been tested by the man-
ufacturer. The testing procedure includes a leak test by pres-
surisation with dry air at 30 Bars for 48 hours of the cooling
circuit, an electrical safety test in accordance with the appli-
cable regulation and a functional unit test with settings be-
ing implemented on the microprocessor, all the components
installed and any accessories supplied.
TMC H/V - Horizontal (horizontal installation)
and Vertical (vertical installation) series
Horizontal installation
Vertical installation
Air cooled condenser and dry cooler
Versions for horizontal and vertical installation and with
V-shaped structure.
Turbocoil heat exchangers made of hot dipped galvanized
metal sheet with copper tubes expanded into aluminum
ns
Casing made of galvanised steel, powder coated Epoxy-
Polyester RAL 9003 resistant to corrosion
High-efciency, low-consumption motors, statically and
dynamically balanced, with permanently greased bear-
ings, in-built overheat protection and integrated protection
grilles
Valid for units with direct expansion circuit only.
Available air-cooled condenser and dry cooler ac-
cessories
Latest generation EC fans for high-energy savings, reduced
noise levels and better regulation of the number of revolu-
tions
Fins coated with ALUPAINT for better aluminum corrosion
protection. (ACC only)
Conguration with multiple circuits or sub cooling circuits