SYSHP MINI EVO P – Installation Operation Manual (IOM SYSHP MINI EVO P S 1GB)
Table Of Contents
3.2 Accessories avaliable from supplier
3 ACCESSORIES
3.1 Accessories supplied with the unit
In heating mode, the water flowing temperature (T1)
range in different outdoor temperature (T4) is listed
below:
In cooling mode, the water flowing temperature
(TW_out) range in different outdoor temperature(T4) is
listed below:
Installation and owner’s
manual(this book)
Quantity
Technical data manual
Y-shape filter
Shape
Name
1
1
1
Installation Fittings
Wired controller
1
1
Drian hose
1
Energy label 1
Network matching
wires
1
In DHW mode, the water flowing temperature(T1)
range in different outdoor temperature(T4) is listed below:
Thermistor for buffer tank temp.(Tbt)
Connection wiring of Tbt sensor
Thermistor for Zone 2 flow temp.(Tw2)
Thermistor for solar temp.(Tsolar)
Thermistor for hot water tank temp.(T5)
06
Maximum length of communication wirings between the unit and the controller is 50m.
Power cords and communication wiring must be laid out separately, they can not be placed in the same conduit.
Otherwise, it may lead to electromagnetic interference. Power cords and communication wirings should not come
in contact with the refrigerant pipe so as to prevent the high temperature pipe from damaging wirings.
Communication wirings must use shielded lines.Including indoor unit to outdoor unit PQE line ,indoor unit to controller
HA and HB line.
-5
10
5 11
19
43
25 50
T4
TW_out
Operation range by heat pump with possible limitation and
protection.
Operation range by heat pump with possible limitation and
protection.
If IBH/AHS setting is valid,only IBH/AHS turns on;
If IBH/AHS setting is invalid,only heat pump turns on,
limitation and protection may occur during heat pump operation.
Heat pump turns off,only IBH/AHS turns on.(IBH can heat the water
temperature up to 65℃, AHS can heat the water temperature up to
70℃)
Maximum inlet water temperature line for heat pump operation.
Operation range by heat pump with possible limitation and
protection.
If IBH/AHS setting is valid,only IBH/AHS turns on;
If IBH/AHS setting is invalid,only heat pump turns on,
limitation and protection may occur during heat pump operation.
Heat pump turns off,only IBH/AHS turns on.IBH can heat the water
temperature up to 65℃, AHS can heat the water temperature up to
70℃
Maximum inlet water temperature line for heat pump operation.
Protect Angle
1
Thermistor for Tbt,Tw2,Tsolar and T5 can be shared. If
necessary, you can purchase other thermistors and
connection wiring from the supplier.
Thermistor(10m) for Tbt
(or Tw2 or Tsolar or T5)
-25
0
5
12
19
35
45
T4
T1
-20
-15
5
24
30
55
60 6540 5025 70
-25
0
5
12
19
35
45
T4
T1
-20
-15
5
24
30
55
60 6540 5025
43
70