SYSHP MINI EVO P – Installation Operation Manual (IOM SYSHP MINI EVO P S 1GB)

50
t_DRYUP
Temp-down days for floor drying up
8
t_HIGHPEAK
Days for floor drying up
5
t_DRYD
5
t_DRYPEAK
Outlet temperature of floor drying up
45
START TIME
The start time of floor drying up
Hour
the
present
time(not on
the hour +1,
on the hour
+2)
Minute:00
START DATE
The start date of floor drying up
The present
date
13.1
AUTO RESTART
COOL/HEAT MODE
Enable or disable the auto restart cooling/heating
mode. 0=NON,1=YES
1
13.2
AUTO RESTART DHW
MODE
Enable or disable the auto restart DHW mode.
0=NON,1=YES
1
14.1
POWER INPUT
LIMI
TATION
0
7.14 GAS_COST Price of gas 0.85
7.15 ELE_COST
Price of electricity
0.20
7.16 MAX_SETHEATER
Maximum setting temperature of additional heating source
80
7.17 MIN_SETHEATER Minimum setting temperature of additional heating source 30
7.18 MAX_SIGHEATER
The voltage corresponding to the maximum setting
temperature of additional heating source
10
7.21 dT5_TBH_OFF
The temperature difference between T5 and T5S(The set
water tank temperature) that turns the booster heater off.
5
7.22 t_TBH_DELAY
The time that the compressor has run before starting the
booster heater
30
7.23 T4_TBH_ON
The ambient temperature for starting the tank booster
heater
5
7.24 P_TBH
Power input of TBH
2
7.25 SOLAR FUNCTION
Enable or disable the SOLAR function0=NON,1=ONLY
SOLAR, 2=SOLAR+HPHEAT PUMP
0
7.26 SOLAR CONTROL
The solar pump pump_s) control method 0=Tsolar,
1=SL1SL2
0
7.27 DELTASOL 10
8.1 T1S_H.A_H
The target outlet water temperature for space heating
in holiday away mode
25
8.2 T5S_H.A_DHW
The target tank temperature f or domestic hot
water heating in holiday away mode
25
PREHEATING FOR
FLOOR-T1S
The setting temperature of outlet water during first
preheating for floor
25
t_FIRSTFH
Running time for first preheating of the floor
72
7.20
TBH FUNCTION
Enable or disable the TBHTANK BOOSTER HEATER
function0=NON,1=YES
1
The voltage corresponding to the minimum setting
temperature of additional heating source
3
7.19
MIN_SIGHEATER
The deviation temperature that SOLAR turns on
Order
number
Code State Default
FLOOR DRYING UP
The function of drying up the floor
Temp-up days for floor drying up
The type of power input limitation
DAY
DAY
DAY
°C
h/min
/
/
/
€/m
3
€/kWh
V
min
kW
/
/
HOUR
/
V
Unit
°C
°C
°C
°C
°C
°C
°C
°C
12.1
d/m/y
12.2
/ /
12.1