- 1 User Interface Field Settings
- 1.1 Introduction
- 1.2 Menu Structure
- 1.3 FOR SERVICEMAN Menu
- 1.4 DHW MODE SETTING Menu
- 1.5 COOL MODE SETTING Menu
- 1.6 HEAT MODE SETTING Menu
- 1.7 AUTO MODE SETTING Menu
- 1.8 TEMP. TYPE SETTING Menu
- 1.9 ROOM THERMOSTAT Menu
- 1.10 OTHER HEATING SOURCE Menu
- 1.11 HOLIDAY AWAY SETTING Menu
- 1.12 SERVICE CALL Menu
- 1.13 RESTORE FACTORY SETTINGS
- 1.14 TEST RUN
- 1.15 SPECIAL FUNCTION
- 1.16 AUTO RESTART
- 1.17 POWER INPUT LIMITATION
- 1.18 INPUT DEFINE
- 1.19 CASCADE SET
- 1.20 HMI ADDRESS SET
- 1.21 COMMON SET
- 2 Operation parameter
- 1 User Interface Field Settings
69
1.9 ROOM THERMOSTAT Menu
MENU > FOR SERVICEMAN > ROOM THERMOSTAT
As an alternative to control space heating/cooling modes according to the leaving
water temperature and/or the room temperature detected by the temperature
sensor inside the user interface, separate room thermostat can be installed and used
to control space heating/cooling modes.
ROOM THERMOSTAT sets whether or not room thermostats are installed:
ROOM THERMOSTAT = NON: No room thermostat.
ROOM THERMOSTAT=ONE ZONE: Room thermostat provides the switch signal to unit.
ROOM THERMOSTAT=DOUBLE ZONE: Indoor unit is connected with two room thermostat.
ROOM THERMOSTAT = MODE SET: Room thermostat can control heating and cooling individually.
If ROOM THERMOSTAT is set as MODE SET, the interface appears:
MODE SET PRIORITY sets whether cooling mode or heating mode takes priority. When CL port and HL port close at the
same time, heat pump will run corresponding to the MODE SET PRIORITY setting.
1.10 OTHER HEATING SOURCE Menu
1.10.1 OTHER HEATING SOURCE menu overview
MENU > FOR SERVICEMAN > OTHER HEATING SOURCE
OTHER HEATING SOURCE menu
IBH FUNCTION set IBH runs for heat mode or heat+DHW mode
IBH LOCATE means IBH is installed for pipe heating. (Default setting: PIPE LOOP)
MODE SET
6 ROOM THERMOSTAT
6.1 ROOM THERMOSTAT
6.2. MODE SET PRIORITY
ADJUST
HEAT
5°C
30MIN
-5°C
HEAT
7 OTHER HEATING SOURCE
7.1 IBH FUNCTION
7.2 IBH LOCATE
7.3 dT1_IBH_ON
7.4 t_IBH_DELAY
7.5 T4_IBH_ON
ADJUST
1/6
PIPE LOOP
7 OTHER HEATING SOURCE
7.6 P_IBH1
7.7 P_IBH2
7.8 AHS FUNCTION
7.9 AHS_PUMPI CONTROL
7.10 dT1_AHS_ON
ADJUST
2/6
5°C
0.0kW
NON
RUN
0.0kW
-5°C
7 OTHER HEATING SOURCE
7.11 t_AHS_DELAY
7.12 T4_AHS_ON
7.13 EnSWITCHPDC
7.14 GAS_COST
7.15 ELE_COST
ADJUST
3/6
30MIN
NON
0.85
0.20
10V
80° C
7 OTHER HEATING SOURCE
7.16 MAX_SETHEATER
7.17 MIN_SETHEATER
30°C
7.18 MAX_SIGHEATER
7.19 MIN_SIGHEATER
7.20 TBH FUNCTION
ADJUST
4/6
3V
YES
5 ° C
30MIN
2,0kW
NON
7 OTHER HEATING SOURCE
7.21 dT5_TBH_OFF
7.22 t_TBH_DELAY
7.23 T4_TBH_ON
7.24 P_TBH
7.25 SOLAR FUNCTION
ADJUST
5/6
5°C
7 OTHER HEATING SOURCE
7.26 SOLAR CONTROL
7.27 DELTATSOL
ADJUST
6/6
Tsolar
10°C
ROOM THERMOSTAT menu
NON
6 ROOM THERMOSTAT
6.1 ROOM THERMOSTAT
ADJUST