Manual Ribbed pipe radiator
EN
Ribbed pipe radiator
10
-Electronic room temperature control
plus week timer
-Room temperature control with open
window detection
-Adaptive start control
The product can be controlled in a different
way, e.g. by an overall control system (BMS),
but in that case the responsibility lies with the
installer to ensure that the control system is
programmed to make the installation meet
the requirements of Ecodesign Regulation (EU)
2015/1188.
Start-up
When the unit is used for the rst time or after
a long period of disuse, smoke or odour may
result from dust or dirt that has collected on
the element. This is completely normal and
disappears after a short time.
Packaging
Packaging materials are chosen with
consideration to environment and are therefore
recyclable.
Handling of product at end of working
life
This product may contain substances necessary
for functionality of product but potentially
dangerous for the environment. The product
should not be disposed mixed with general
household waste but delivered to a designated
collection point for environmental recycling.
Please contact local authority for further details
of your nearest designated collection point.
Installation and operating instructions
General Instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid if the product is used in
the manner intended and in accordance with the
instructions.
The FRICO ribbed pipe radiators are
manufactured by steel pipes with ribbed ns.
The ends are constructed in such a way that
they can be used as mounting consoles. The
radiators have a reset overheat protection of
type capillary tube. The reset of the overheat
protection is made, after that the reason for the
fault has been found and solved, by pressing
the reset switch on the inside of the cover. All
types are approved for stationary mounting
in dry, humid and wet facilities as well as in
garages. Furthermore, the sand lled radiators
are approved for mounting in rooms where
there is a risk for re. IP44
Mounting
The radiators are to be horizontally mounted
on the wall with 4 screws. As you can see from
the existing ”key holes”. of the mounting
supports, the radiator shall be mounted with
the connection side to the left, seen from the
front. The two lower mounting holes are used
to lock the radiator. For min. distances, see the
dimension drawing. A oor bracket FBRP is
available as an accessory.
Installation
The ribbed pipe radiator is intended for
permanent installation. The installation, which
should be preceded by an omnipolar switch
with a contact separation of at least 3 mm,
should only be wired by a competent electrician
and in accordance with the latest edition of IEE
wiring regulations.
Control
When using this product as a local space
heater according to Ecodesign Regulation (EU)
2015/1188, it must be supplemented with one
of the following approved controls.
• TAP16R, electronic thermostat that includes: