EDM SYSHP MINI SPLIT TANK

58
1.14 TEST RUN
1.14.1 TEST RUN Menu overview
MENU > FOR SERVICEMAN > TEST RUN
TEST RUN is used to check that the valves, air purge funcon, circulaon pump, space cooling mode, space heang mode and
DHW mode are all operang correctly.
TEST RUN start screen and TEST RUN menu
Exit air purge screen
POINT CHECK menu
During test run, all buons except OK are invalid. If you want to turn o the test run, please press OK. For example ,when the unit
is in air purge mode, aer you press OK, the following page will be displayed:
1.14.2 POINT CHECK menu
MENU > FOR SERVICEMAN > TEST RUN > POINT CHECK
The POINT CHECK menu is used to check the operaon of individual components. Use ▼▲ to scroll to the components you want
to check and press ON/OFF to toggle the on/o state of the component. If a valve does not turn on/o when its on/o state is
toggled or if a pump/heater does not operate when turned on, check the components connecon to the hydronic system main
PCB.