EDM SYSHP MINI SPLIT TANK
57
1.11 HOLIDAY AWAY SETTING Menu
MENU > FOR SERVICEMAN > HOLIDAY AWAY SETTING
The HOLIDAY AWAY SETTING menu sengs are used to set the outlet water
temperature to prevent water pipes freezing when away from home in cold
weather seasons. In HOLIDAY AWAY SETTING the following parameters should
be set.
T1S_H.A._H sets the heat pump’s leaving water set temperature for space
heang mode when in holiday away mode.
T5S_H.A._DHW sets the heat pump’s leaving water set temperature for DHW
mode when in holiday away mode.
1.12 SERVICE CALL Menu
MENU > FOR SERVICEMAN > SERVICE CALL
In SERVICE CALL the following parameters can be set.
PHONE NO. and MOBILE NO. can be used to set aer-sales service contact numbers. If set, these numbers are displayed to users
in MENU > FOR SERVICEMAN > SERVICE CALL
Use ▼ ▲ to adjust the numerical values. The maximum length of the phone numbers is 14 digits.
The black rectangle found between 0 and 9 when scrolling up and down using ▼ ▲ is
converted to a blank space when
the phone numbers are displayed to users in MENU > FOR SERVICEMAN > SERVICE
CALL and can be used for phone numbers less than 14 digits in length.
1.13 RESTORE FACTORY SETTINGS
MENU > FOR SERVICEMAN > RESTORE FACTORY SETTINGS
RESTORE FACTORY SETTINGS is used to restore all the parameters set in the user interface to their factory defaults.
On selecng YES, the process of restoring all sengs to their factory defaults begins and progress is displayed as a percentage.
HOLIDAY AWAY SETTING menu
SERVICE CALL menu
RESTORE FACTORY SETTINGS screens