1.8 TEMP. TYPE SETTING Menu
MENU > FOR SERVICEMAN > TEMP. TYPE SETTING
The TEMP. TYPE SETTING is used for selecng whether the water ow temperature
or room temperature is used to control the ON/OFF of the heat pump.
When ROOM TEMP. is enabled, the target water ow temperature will be calculated
from climate-related curves.
For installaons without room thermostats, space heang and cooling modes can be
controlled in one of two dierent ways:
▪ according to the Heat Pump leaving water temperature alone
▪ according to the room temperature detected by the Heat Pump Split user
interface’s built-in temperature sensor alone
WATER FLOW TEMP. sets whether space heang/cooling modes are controlled
according to the Heat Pump leaving water temperature. If YES is selected, the user is
able to set the Heat Pump Split unit’s leaving water temperature set temperature on
the user interface’s main screen.
ROOM TEMP. sets whether space heang/cooling modes are controlled according to
the room temperature detected by the temperature sensor in the Heat Pump Split
user interface. If YES is selected, the user is able to set the room temperature set
temperature on the user interface’s main screen, no maer what is the seng of
WATER FLOW TEMP.
DOUBLE ZONE sets whether there are two zones.
If set WATER FLOW TEMP. and ROOM TEMP. to YES, meanwhile set DOUBLE ZONE to
NON or YES, the following pages will be displayed. In this case, the seng value of
zone 1 is T1S, the seng value of zone 2 is T1S2 (The corresponding TIS2 is calculated
according to the climate related curves.)
TEMP. TYPE SETTING menu
Only set WATER FLOW TEMP to YES
Only set ROOM TEMP to YES
Set WATER FLOW TEMP. and ROOM TEMP. to YES; Set DOUBLE ZONE to NON or YES
Homepage (zone 1)
Addion page (zone 2)
(Double zone is eecve)
If set DOUBLE ZONE to YES and set ROOM TEMP. to NON, meanwhile set WATER FLOW TEMP. to YES or NON, the following pages
will be displayed. In this case, the seng value of zone 1 is T1S, the seng value of zone 2 is T1S2.