EDM SYSHP MINI SPLIT TANK
53
t_INTERVAL_H sets the heang mode compressor re-start delay. When the compressor stops running, it will not re-start unl
at least t_INTERVAL_H minutes have elapsed.
T1SetH1 sets the temperature 1 of automac seng curve for heang mode.
T1SetH2 sets the temperature 2 of automac seng curve for heang mode.
T4H1 sets the ambient temperature 1 of automac seng curve for heang mode.
T4H2 sets the ambient temperature 2 of automac seng curve for heang mode.
ZONE1 H-EMISSION sets the emission type for heang mode.
ZONE2 H-EMISSION sets the emission type for heang mode.
1.7 AUTO MODE SETTING Menu
MENU > FOR SERVICEMAN > AUTO MODE SETTING
In AUTO MODE SETTING the following parameters should be set.
T4AUTOCMIN sets the ambient temperature below which the heat pump
will not provide chilled water for space cooling in auto mode.
T4AUTOHMAX sets the ambient temperature above which the heat pump
will not provide heated water for space heang in auto mode.
T4AUTOCMAX, T4AUTOCMIN
Abreviaons:
HP: Heat pump
AHS: Addional heang source
IBH: Backup electric heater
T4CMAX: The ambient temperature above which the heat pump will not operate in cooling mode.
T4HMIN: The ambient temperature below which the heat pump will not operate in heang mode.
AUTO MODE SETTING menu
COOL
OFF OFF
Heat mode by
IBH or AHS
Heat mode by
heat pump