8.3 FOR SERVICEMAN Menu
FOR SERVICEMAN allows installers to input the system conguraon and set the
system parameters. To enter FOR SERVICEMAN, go to MENU > FOR SERVICEMAN.
Enter the password, using ◄ ► to navigate between digits and using ▼ ▲ to adjust
the numerical values, and then press OK. The password is 234.
Then the following pages will be displayed aer pung the password.
FOR SERVICEMAN password screen
FOR SERVICEMAN menu
1.4 DHW MODE SETTING Menu
1.4.1 DHW MODE SETTING menu overview
MENU > FOR SERVICEMAN > DHW MODE SETTING
DHW MODE SETTING menu
In DHW MODE SETTING the following parameters should be set.
DHW MODE enables or disables DHW mode. For installaons with DHW tanks, select YES to enable DHW mode. For installaons
without DHW tanks, select NON to disable DHW mode.
DISINFECT sets whether or not the disinfecon operaon is performed.
DHW PRIORITY sets whether domesc hot water heang or space heang/cooling takes priority. If NON is selected in the DHW
PRIORITY mode, when it is available and the space heang/cooling is OFF, the heat pump will heat the water as required. If space
heang/cooling is ON, the water will be heated as required when the immersion heater is unavailable.