EDM SYSHP MINI SPLIT TANK
Model name SYSHP MINI
SPLIT ODU 12 Q SPLIT ODU 14 Q SPLIT ODU 16 Q
Indoor Unit Model SYSHP MINI SPLIT TANK 240 Q
Heang
A7W35
Capacity kW
12.1 14.5 16.0
Rated input kW 2.44 3.09 3.56
COP 4.95 4.70 4.50
A7W45
Capacity kW 12.3 14.2 16.0
Rated input kW 3.24 3.89 4.44
COP
3.80 3.65 3.60
A-7W35
Capacity kW 10.0 12.0 13.3
Rated input kW 3.33 4.29 4.93
COP 3.00 2.80 2.70
A-7W55
Capacity kW 10.0 11.0 12.5
Rated input kW 4.88 5.37 6.19
COP 2.05 2.05 2.02
Cooling
A35W18
Capacity kW 12.0 13.5 14.9
Rated input kW 3.0 3.75 4.38
EER 4.0 3.6 3.4
A35W7
Capacity kW 11.6 12.7 14.0
Rated input kW 4.22 4.98 5.71
EER 2.75 2.55 2.45
DHW
Tapping prole according EN16147 XL
Water heang
energy eciency
class(1)
Warm climate
class A+ A+ A+
COP 3.73 3.73 3.73
Average climate
class A+ A+ A+
COP 3.00 3.00 3.00
Cold climate
class A A A
COP 2.24 2.24 2.24
Seasonal space heang
energy eciency class(2)
Water outlet at 35⁰C
class A+++ A+++ A+++
SCOP 4.81 4.72 4.62
Water outlet at 55⁰C
class A++ A++ A++
SCOP 3.45 3.47 3.41
Rated water ow m3/h 2.08 2.49 2.75
Outdoor
Unit
Power supply V/Ph/Hz 220-240/1/50
Rated input W 5400 5700 6100
Rated current A 24.5 25.0 26.0
Unit dimension (W×H×D) mm 1118×865×523
Packing dimension (W×H×D) mm 1190×970×560
Net/Gross weight kg 100/113.5
Refrigerant
Type(GWP) R32(675)
Charged volume kg 1.84
Refrigerant to be added g/m 38
Refrigerant
piping connecons
Liquid/Gas side mm Φ9.52 / Φ15.9
Max. piping length m 30
Max. dierence in height m 20
16