OM SYSHP MINI SPLIT
T1SetC1
T1SetC2
T4C1
T4C2
T1SetH1
T1SetH2
The type of power input limitation, 0=NON, 1~8=type 1~8, default:0
range:0.5~6 hour, setting interval:0.5 hour,
sending value=actural value*2
range:0.5~6 hour, setting interval:0.5 hour,
sending value=actural value*2
range:2~20 hour, setting interval:0.5 hour,
sending value=actural value*2:
261 (PLC: 40262)
262 (PLC: 40263)
263
(PLC: 40264
)
264 (PLC: 40265)
265 (PLC: 40266)
266 (PLC: 40267)
267 (PLC: 40268)
268 (PLC: 40269)
269 (PLC: 40270)
270 (P LC: 40271
)
271 (PLC: 40272)
272 (PLC: 40273)
T4H1
T4H2
HB:t_T4_FRESH_C
LB:t_T4_FRESH_H
T_PUMPI_DELAY
EMISSION TYPE
Parameter of the ninth temperature curves for cooling mode,
range:5~25 ć, default setting: 10 ć;
Parameter of the ninth temperature curves for cooling mode,
range:5~25 ć, default setting: 16 ć;
Parameter of the ninth temperature curves for cooling mode,
range:(-5)~46 ć, default setting: 35 ć;
Parameter of the ninth temperature curves for cooling mode,
range:(-5)~46 ć, default setting: 25 ć;
Parameter of the ninth temperature curves for cooling mode,
range:25~60 ć, default setting: 35 ć;
Parameter of the ninth temperature curves for cooling mode,
range:25~60 ć, default setting: 28 ć;
Parameter of the ninth temperature curves for cooling mode,
range:(-25)~30 ć, default setting: -5 ć;
Parameter of the ninth temperature curves for cooling mode,
range:(-25)~30 ć, default setting: 7 ć;
Bit12-15: The type of zone 2 end for cooling mode
Bit8-11: The type of zone 1 end for cooling mode
Bit4-7: The type of zone 2 end for heating mode
Bit0-3: The type of zone 1 end for heating mode
58