EDM SYSHP MINI SPLIT 06 16
Table Of Contents
- CONTENTS
- CONTENTS
- 1.1 System Schematic
- 1.2 System Configurations
- 2 Unit Capacities
- 2.1 Outdoor unit
- 3 Nomenclature
- 3.1 Outdoor unit
- 3.2 Hydronic box
- 4 System Design and Unit Selection
- 4.1 Selection procedure
- 4.2 M thermal Leaving Water Temperature (LWT) Selection
- 5 Typical Applications
- 5.1 Space Heating Only
- 5.2 Space Heating and Domestic Hot Water
- 5.3 Space Heating, Space Cooling and Domestic Hot Water
- 5.4 Space Heating and Domestic Hot Water (Bivalent)
- 5.4.2 Auxiliary heat source provides space heating and domestic hot water
- 5.5 Space Heating Through Floor Heating Loops and Radiators
- 5.6 Space Heating, Space Cooling and Domestic Hot Water Compatible with Solar Water Heater
- Part 2 Engineering Data
- 1.1 Outdoor Unit
- 1.2 Hydronic Box
- 2 Dimensions and Center of Gravity
- 2.1 Outdoor Unit
- 2.2 Hydronic Box
- 3.1 Outdoor Unit
- 4 Wiring Diagrams
- 4.1 Outdoor Unit
- 4.2 Hydronic Box
- 5 Capactiy Tables
- 5.2 Cooling Capacity Tables (Test standard:EN14511)
- 7 Hydronic Performance
- 8.1 Overall
- 8.2 Octave Band Levels
- 9.1 Outdoor Unit
- 1.1 Notes for Installers Boxes
- 2 Installation
- 2.1 Acceptance and Unpacking
- 2.3 Outdoor unit
- 1
- 1.1
- 1.2
- 1.3
- 1.4
- 1.5
- 2.4 Hydronic box
- 3 Refrigerant Pipework
- 3.1 Permitted Piping Length and Level Difference
- 3.3 Procedure and Principles
- 3.4 Storing Copper Piping
- 3.8 Pipe Flushing
- 3.9 Gastightness Test
- 4 Water Pipework
- 4.1 Water Circuit Checks
- 4.2 Water volume and sizing expansion vessels
- 4.3 Water Circuit Connection
- 4.4 Water Circuit Anti-freeze Protection
- 5.1 General
- 5.4 Wiring Overview
- 8.1 Introduction
- 8.2 Menu Structure
- 8.11 HOLIDAY AWAY SETTING Menu
- 8.14 TEST RUN
- 8.15 SPECIAL FUNCTION
- 8.16 AUTO RESTART
- 8.20 HMI ADDRESS SET
- 9 Operation parameter
- 10 Network Configuration Guidelines
- 10.1 Install APP
- 10.2 Sign in
- 10.3 Add device and login to home Wi-Fi
- 10.4 Wired Controller Setting
- 10.4.2 Finishing up
- 11 USB Function Guidelines
- 11.1 Parameters setting transfer between wired controllers
- 11.2 Convenient program upgrade for unit
- 12 Climate Related Curves
- 13 Error Code Table
- Part 1 General Information
- Part 2 Engineering Data
- Part 3
- Installation and Field Settings
- 1 Air-to-Water HP Split System
- 2 Unit Capacities
- 3 Nomenclature
- 4 System Design and Unit Selection
- 5 Typical Applications
- 1 Specifications
- 3 Piping Diagrams
- 4 Wiring Diagrams
- 5 Capactiy Tables
- 6 Operating Limits
- 7 Hydronic Performance
- 8 Sound Levels
- 9 Accessories
- 1 Preface to Part 3
- 3 Refrigerant Pipework
- 4 Water Pipework
- 6 DIP Switch Settings
- 7 Internal Circulation Pump
- 8 User Interface Field Settings
- 9 Operation parameter
- 10 Network Configuration Guidelines
- 11 USB Function Guidelines
- 12 Climate Related Curves
- 13 Error Code Table
89
Abbreviaons:
T5: DHW tank water temperature
T5S: DHW set temperature
T5stop: DHW mode leaving water temperature operang limit
Figure 3-8.8: DHW tank disinfecon
Abbreviaons:
T5: DHW tank water temperature
T5S: DHW set temperature
Figure 3-8.9: Operaon in DHW PRIORITY
t_INTERVAL_DHW sets the DHW mode compressor re-start delay. When the compressor stops running, it will not re-start unl at
least t_INTERVAL_DHW minutes have elapsed.
dT5_TBH_OFF sets the temperature dierence between the DHW set temperature (T5S) and the DHW tank water temperature
(T5) below which the immersion is not used. When T5 > Min(T5Stop+dT5_TBH_OFF, 65°C), the immersion heater is o.
T4_TBH_ON sets the ambient temperature above which the immersion heater will not be used.
t_TBH_DELAY sets the delay between the compressor starng and the immersion heater being turned on.
T5S_DI sets the DHW tank disinfecon operaon target temperature. Cauon: during the disinfecon operaon (duraon: t_DI_
MAX) the domesc hot water temperature at the hot water taps will at mes be equal to the value set for T5S_DI.
t_DI_HIGHTEMP sets that length of me that the DHW tank disinfecon operaon target temperature is maintained.
t_DI_MAX sets the total duraon of the DHW tank disinfect operaon.
t_DHWHP_RESTRICT sets the maximum length of me that the heat pump will
run in space heang or space cooling modes before switching to DHW mode, if a
requirement for DHW mode exists. When running in space heang mode or space
cooling mode, the heat pump becomes available for DHW mode either as soon as
the space heang/cooling set temperatures have been reached (refer to Part 3,
8.5 “COOL MODE SETTING Menu” and Part 3, 8.6 “HEAT MODE SETTING Menu”)
or aer t_DHWHP_MAX minutes have elapsed.
t_DHWHP_MAX sets the maximum length of me that the heat pump will run in DWH mode before switching to space heang
mode or space cooling mode if a requirement for space heang/cooling modes exists. When running in DHW mode, the heat
pump becomes available for space heang/cooling either as soon as the DHW tank water temperature (T5) reaches the DHW set
temperature (T5S) or aer t_DHWHP_MAX minutes have elapsed.
Figure 3-8.9 illustrates the eects of t_DHWHP_MAX and t_DHWHP_RESTRICT when DHW PRIORITY is enabled. The heat pump
inially runs in DWH mode. Aer t_DHWHP_MAX minutes, T5 has not reached
DHWPUMP TIME RUN sets whether or not the user is able to set the DHW pump (eld supply) in DHW mode. For installaons
with a DHW pump, select ON so that the user is able to set pump start mes.
Time
Restart
Hreang
water
Space
heang/
cooling
Hreang
water
Time