Figure 3-2.4: 4-6kW models drainage hole
Figure 3-2.3: Outdoor unit xing
2.3.6 Drainage
Drainage ditch should be provided to allow drainage of condensate that may form on the air side heat exchanger when the unit
is running in heang mode or domesc hot water mode. The drainage should ensure that condensate is directed away from
roadways and footpaths, especially in locaons where the climate is such that condensate may freeze.
Fix the unit securely to foundaon by means of the Φ10 expansion bolt. It is best to screw in the foundaon bolts unl
their length is 20 mm from the foundaon surface.
Φ10 Expansion
bolt
Rubber
shocking
proof mat
Solid
ground
or roong
Concrete
basement
h≥100mm
(unit: mm)
Drain hole
This drain hole is covered by rubber plug.
If the small drain hole can not meet the
drainage requirements, the big drain hole
can be used at the same me.