t_interval_H: Compressor re-start delay in space heang mode. (Refer to Part 3,
8.6 “HEAT MODE SETTING Menu”).
8.15 SPECIAL FUNCTION
8.15.1 SPECIAL FUNCTION menu overview
MENU > FOR SERVICEMAN > SPECIAL FUNCTION
SPECIAL FUNCTION is used to pre-heang oor and drying up
oor once installaon is complete or the rst me start up the
unit or restart the unit aer a long me stop.
Figure 3-8.40: Special funcons menu
Figure 3-8.42: Preheang for oor
8.15.2 PREHEATING FOR FLOOR
MENU > FOR SERVICEMAN > SPECIAL FUNCTION > PREHEATING FOR FLOOR
Before oor heang, if a large amount of water remains on the oor, the oor may be warped or even rupture during oor heang
operaon, in order to protect the oor, oor drying is necessary, during which the temperature of the oor should be increased
gradually.
During rst operaon of the unit, air may remain in the water system which can cause malfuncons during operaon. It is
necessary to run the air purge funcon to release the air (make sure the air purge valve is open).
T1S sets the heat pump’s leaving water set temperature in preheang for oor
mode.
t_fristFH sets the duraon of preheang for oor mode.
The operaon of the unit during preheang for oor mode is illustrated in Figure
3-8.42.
Figure 3-8.41: Preheang for oor menu
Compressor
Pump
Whilst the preheang for oor operaon is running, the number of minutes that it has been running for and the heat pump’s
leaving water temperature are displayed on the user interface. During the preheang for oor operaon all buons except OK
are inacvated. To exit the preheang for oor operaon, press OK and then select YES when prompted. Refer to Figure 3-8.43.