EDM SYSHP MINI SPLIT 06 16
Table Of Contents
- CONTENTS
- CONTENTS
- 1.1 System Schematic
- 1.2 System Configurations
- 2 Unit Capacities
- 2.1 Outdoor unit
- 3 Nomenclature
- 3.1 Outdoor unit
- 3.2 Hydronic box
- 4 System Design and Unit Selection
- 4.1 Selection procedure
- 4.2 M thermal Leaving Water Temperature (LWT) Selection
- 5 Typical Applications
- 5.1 Space Heating Only
- 5.2 Space Heating and Domestic Hot Water
- 5.3 Space Heating, Space Cooling and Domestic Hot Water
- 5.4 Space Heating and Domestic Hot Water (Bivalent)
- 5.4.2 Auxiliary heat source provides space heating and domestic hot water
- 5.5 Space Heating Through Floor Heating Loops and Radiators
- 5.6 Space Heating, Space Cooling and Domestic Hot Water Compatible with Solar Water Heater
- Part 2 Engineering Data
- 1.1 Outdoor Unit
- 1.2 Hydronic Box
- 2 Dimensions and Center of Gravity
- 2.1 Outdoor Unit
- 2.2 Hydronic Box
- 3.1 Outdoor Unit
- 4 Wiring Diagrams
- 4.1 Outdoor Unit
- 4.2 Hydronic Box
- 5 Capactiy Tables
- 5.2 Cooling Capacity Tables (Test standard:EN14511)
- 7 Hydronic Performance
- 8.1 Overall
- 8.2 Octave Band Levels
- 9.1 Outdoor Unit
- 1.1 Notes for Installers Boxes
- 2 Installation
- 2.1 Acceptance and Unpacking
- 2.3 Outdoor unit
- 1
- 1.1
- 1.2
- 1.3
- 1.4
- 1.5
- 2.4 Hydronic box
- 3 Refrigerant Pipework
- 3.1 Permitted Piping Length and Level Difference
- 3.3 Procedure and Principles
- 3.4 Storing Copper Piping
- 3.8 Pipe Flushing
- 3.9 Gastightness Test
- 4 Water Pipework
- 4.1 Water Circuit Checks
- 4.2 Water volume and sizing expansion vessels
- 4.3 Water Circuit Connection
- 4.4 Water Circuit Anti-freeze Protection
- 5.1 General
- 5.4 Wiring Overview
- 8.1 Introduction
- 8.2 Menu Structure
- 8.11 HOLIDAY AWAY SETTING Menu
- 8.14 TEST RUN
- 8.15 SPECIAL FUNCTION
- 8.16 AUTO RESTART
- 8.20 HMI ADDRESS SET
- 9 Operation parameter
- 10 Network Configuration Guidelines
- 10.1 Install APP
- 10.2 Sign in
- 10.3 Add device and login to home Wi-Fi
- 10.4 Wired Controller Setting
- 10.4.2 Finishing up
- 11 USB Function Guidelines
- 11.1 Parameters setting transfer between wired controllers
- 11.2 Convenient program upgrade for unit
- 12 Climate Related Curves
- 13 Error Code Table
- Part 1 General Information
- Part 2 Engineering Data
- Part 3
- Installation and Field Settings
- 1 Air-to-Water HP Split System
- 2 Unit Capacities
- 3 Nomenclature
- 4 System Design and Unit Selection
- 5 Typical Applications
- 1 Specifications
- 3 Piping Diagrams
- 4 Wiring Diagrams
- 5 Capactiy Tables
- 6 Operating Limits
- 7 Hydronic Performance
- 8 Sound Levels
- 9 Accessories
- 1 Preface to Part 3
- 3 Refrigerant Pipework
- 4 Water Pipework
- 6 DIP Switch Settings
- 7 Internal Circulation Pump
- 8 User Interface Field Settings
- 9 Operation parameter
- 10 Network Configuration Guidelines
- 11 USB Function Guidelines
- 12 Climate Related Curves
- 13 Error Code Table
56
1 Preface to Part 3
1.1 Notes for Installers Boxes
The informaon contained in this Engineering Data Book may primarily be of use during the system design stage of a Air-to-Water
Heat Pump Split project. Addional important informaon which may primarily be of use during eld installaon has been placed
in boxes, such as the example below, tled “Notes for installers”.
Notes for installers
▪ Notes for installers boxes contain important informaon which may primarily be of use during eld installaon,
rather than during desk-based system design.
1.2 Denions
In this Engineering Data Book, the term “applicable legislaon” refers to all naonal, local and other laws, standards, codes, rules,
regulaons and other legislaon that apply in a given situaon.
1.3 Precauons
All system installaon including installaon of refrigerant piping, water piping and electrical works must only be carried out by
competent and suitably qualied, cered and accredited professionals and in accordance with all applicable legislaon.