EDM SYSHP MINI SPLIT 06 16
Table Of Contents
- CONTENTS
- CONTENTS
- 1.1 System Schematic
- 1.2 System Configurations
- 2 Unit Capacities
- 2.1 Outdoor unit
- 3 Nomenclature
- 3.1 Outdoor unit
- 3.2 Hydronic box
- 4 System Design and Unit Selection
- 4.1 Selection procedure
- 4.2 M thermal Leaving Water Temperature (LWT) Selection
- 5 Typical Applications
- 5.1 Space Heating Only
- 5.2 Space Heating and Domestic Hot Water
- 5.3 Space Heating, Space Cooling and Domestic Hot Water
- 5.4 Space Heating and Domestic Hot Water (Bivalent)
- 5.4.2 Auxiliary heat source provides space heating and domestic hot water
- 5.5 Space Heating Through Floor Heating Loops and Radiators
- 5.6 Space Heating, Space Cooling and Domestic Hot Water Compatible with Solar Water Heater
- Part 2 Engineering Data
- 1.1 Outdoor Unit
- 1.2 Hydronic Box
- 2 Dimensions and Center of Gravity
- 2.1 Outdoor Unit
- 2.2 Hydronic Box
- 3.1 Outdoor Unit
- 4 Wiring Diagrams
- 4.1 Outdoor Unit
- 4.2 Hydronic Box
- 5 Capactiy Tables
- 5.2 Cooling Capacity Tables (Test standard:EN14511)
- 7 Hydronic Performance
- 8.1 Overall
- 8.2 Octave Band Levels
- 9.1 Outdoor Unit
- 1.1 Notes for Installers Boxes
- 2 Installation
- 2.1 Acceptance and Unpacking
- 2.3 Outdoor unit
- 1
- 1.1
- 1.2
- 1.3
- 1.4
- 1.5
- 2.4 Hydronic box
- 3 Refrigerant Pipework
- 3.1 Permitted Piping Length and Level Difference
- 3.3 Procedure and Principles
- 3.4 Storing Copper Piping
- 3.8 Pipe Flushing
- 3.9 Gastightness Test
- 4 Water Pipework
- 4.1 Water Circuit Checks
- 4.2 Water volume and sizing expansion vessels
- 4.3 Water Circuit Connection
- 4.4 Water Circuit Anti-freeze Protection
- 5.1 General
- 5.4 Wiring Overview
- 8.1 Introduction
- 8.2 Menu Structure
- 8.11 HOLIDAY AWAY SETTING Menu
- 8.14 TEST RUN
- 8.15 SPECIAL FUNCTION
- 8.16 AUTO RESTART
- 8.20 HMI ADDRESS SET
- 9 Operation parameter
- 10 Network Configuration Guidelines
- 10.1 Install APP
- 10.2 Sign in
- 10.3 Add device and login to home Wi-Fi
- 10.4 Wired Controller Setting
- 10.4.2 Finishing up
- 11 USB Function Guidelines
- 11.1 Parameters setting transfer between wired controllers
- 11.2 Convenient program upgrade for unit
- 12 Climate Related Curves
- 13 Error Code Table
- Part 1 General Information
- Part 2 Engineering Data
- Part 3
- Installation and Field Settings
- 1 Air-to-Water HP Split System
- 2 Unit Capacities
- 3 Nomenclature
- 4 System Design and Unit Selection
- 5 Typical Applications
- 1 Specifications
- 3 Piping Diagrams
- 4 Wiring Diagrams
- 5 Capactiy Tables
- 6 Operating Limits
- 7 Hydronic Performance
- 8 Sound Levels
- 9 Accessories
- 1 Preface to Part 3
- 3 Refrigerant Pipework
- 4 Water Pipework
- 6 DIP Switch Settings
- 7 Internal Circulation Pump
- 8 User Interface Field Settings
- 9 Operation parameter
- 10 Network Configuration Guidelines
- 11 USB Function Guidelines
- 12 Climate Related Curves
- 13 Error Code Table
18
18
5.6 Space Heang, Space Cooling and Domesc Hot Water Compable with Solar Water Heater
Floor heang loops and fan coil units are used for space heang and fan coil units are used for space cooling. Domesc hot water
is supplied from the domesc hot water tank connected to both the hydronic box and solar water heater. Solar water pump is
controlled by Tsolar temperature sensor. Balance tank temperature sensor is used to control on/o of heat pump. Once the heat
pump stops, internal pump stops to save energy and then balance tank provides hot water for space heang. In addion, balance
tank temperature control can meet both space heang and domesc hot water needs at the same me.
Note:
1. Balance tank volume requirement
For SYSHP MINI SPLIT HYDRO 06 Q, balance tank volume ≥ 25L
For SYSHP MINI SPLIT HYDRO 10 Q, balance tank volume ≥ 25L
For SYSHP MINI SPLIT HYDRO 16 Q, balance tank volume ≥ 40L
Figure 1-5.8: Space heang, space cooling and domesc hot water compable with solar water heater
Tsolar
Modbus
Legend
1 Outdoor unit 12 Distributor (eld supplied)
2 Hydronic box 13 Collector (eld supplied)
3 Plate heat exchanger 14 Domesc hot water tank (eld supplied)
4 Backup electric heater(oponal) 15 Heat exchanger coil
5 Internal circulator pump 16 Immersion heater
6 User interface(Integrated in hydronic box) 17 Bypass valve (eld supplied)
7 Room thermostat 18 Balance tank (eld supplied)*
8 Stop valve (eld supplied) 19
Balance tank temperature sensor
(oponal)
9 Motorized 3-way valve (eld supplied) FHL 1…n Floor heang loops (eld supplied)
10 External circulator pump (eld supplied) FCU 1…n Fan coil units (eld supplied)
11 Motorized 3-way valve (eld supplied)