5.2 Space Heang and Domesc Hot Water
The room thermostats are not connected to the hydronic box but to a motorized valve. Each room’s temperature is regulated
by the motorized valve on its water circuit. Domesc hot water is supplied from the domesc hot water tank connected to the
hydronic box. A bypass valve is required.
Figure 1-5.2: Space heang and domesc hot water
Legend
1 Outdoor unit 10 Distributor (eld supplied)
2 Hydronic box 11 Collector (eld supplied)
3 Plate heat exchanger 12 Bypass valve (eld supplied)
4 Backup electric heater(oponal) 13
Domesc hot water tank (eld supplied)
5 Internal circulator pump 14
Heat exchanger coil
6 User interface 15
Immersion heater
7 Stop valve (eld supplied) FHL 1...n Floor heang loops (eld supplied)
8 Motorized 3-way valve (eld supplied) M1...n Motorized valves (eld supplied)
9
External circulator pump (eld supplied)
T1…n Room thermostats (eld supplied)