TUV IT 13 ATEX 039 X REV 2

[13]
SCHEDULE
[14]
E
U
-TYPE EXAMINATION CERTIFICATE
N
o.
TÜV I
T
13
ATEX
03
9
X
Rev.2
This certificate may only be reproduced in its entirety and without any change, schedule included
.
p
ag
e
4
of
5
PEX-01-M002_r0
8
del
07
/0
8
/2018
[17]
Special conditions for safe use
The
motor
complete
with
integrated
cable
gland
is
suita
ble
for
use
in
the
case
of
one
cable diameter as shown on the rubber of the cable itself.
When replacing the screws of the housing anti-explosion p
arts you will have to choose:
-
For locking screws: steel or sta
inless steel as a minimum
quality class
8.8
-
For tie rods: steel or stainless steel as a minimum
quality class
4.8
For
the
integral
cable
version,
the
user
must
connect
th
e
free
end
of
the
cable
or
in
a
safe area or inside an enclosure with protection Ex d or Ex e
.
The
size
56
step
motor
shaft
has
a
maximum
gap
of
0.20
mm
(instead
of
0.25
mm
as
per table 2 of EN 60079-1)
.
For IPx6 mandatory use of sealing rings on the motor shaft (Corteco) or V ring
.
For motor without cooling fan
,
output power is derated to 50%
.
[18]
Essential Health and Safety Requirements
Assured by compliance with the standards set out in the [9].
[19
]
Drawings and Documents
Listed documents
(prot.
229382
+ 722178354
-5
)
Title:
Description:
Pag
.
:
Rev:
Date:
00 Dossier de
certification
e
Document list
02
-
08/11/2018
0
1
Safety notes
Motors RL series safety and assembling
instructions manual
0
5
0
6
08/11/2018
0
2
Technical note
Technical note
motors series
RL
1
6
0
2
10/2018
03
MEC
56
DWG: Assembly motor RL56
01
00
23/10/2006
04
MEC 63
DWG: Assembly motor RL63
01
00
24/10/2006
05
MEC 71
DWG: Assembly motor RL71
01
00
25/10/2006
06
MEC 80
DWG: Assembly motor RL80
01
00
26/10/2006
07
MEC 90
DWG: Assembly motor RL90
01
00
27/10/2006
08
MEC 100
DWG: Assembly motor RL100
01
00
20/03/2007
09
MEC 112
DWG: Assembly motor RL112
01
00
21/03/2007
10
MEC 132
DWG: Assembly motor RL132
01
00
02/04/2008
11
MEC 16
0
DWG: Assembly motor RL160
01
00
01/04/2008
12
Tappo
RL 56-63-
71-80-90
DWG:
Cap ,
m
otors RL 56-63-71-80-90
without terminal box
01
00
09/03/2007
13
RAEL MEC D001
Wires cabling motor box
RL 56-63-71-80-90 version
d
01
0
1
25/02/2005
14
RAEL MEC
DE001
Wires cabling motor box
RL 56-63-71-80-90 version
d e
01
0
2
18/06/2006
15
RL 100-112
versione 'd'
Wires cabling motor box
RL 100-112 versione
d
01
00
19/02/2007
16
RL 100-112
versione 'd e'
Wires cabling motor box
RL 100-112 versione
d e
01
00
19/02/2007