MANUAL INSTALLATION BF 100MX
17
*the90m
3
/hsettingisavailablein“throughwall”installationonly
(§7).
INTERMEDIATE SPEED (b)
m
3
/h Display l/s Display
22
b22
6
b06
29
b29
8
b08
36
b36
10
b10
47(default)
b47
13
b13
54
b54
15
b15
65
b65
18
b18
72
b72
20
b20
90*
b90
25
b25
5) MAXIMUM SPEED
Themaximumspeed,settablefrom29to90m
3
/h(i.e.from8to25l/s),canbeactivatedthroughexternal
switch, ambient sensor or light switch.
Themaximumspeedcanbesetinthefollowingway:
-presstheMENUbuttonuntilthe“B”(8) letterisdisplayed.
-pressthebuttons+or-toincreaseordecreasethemaximumspeedbetweenthevaluesshowninthe
table below:
*the90m
3
/hsettingisavailablein“throughwall”installationonly
(§7).
MAXIMUM SPEED (8)
m
3
/h Display l/s Display
29
829
8
808
47
847
13
813
54
854
15
815
65
865
18
818
72
872
20
820
90*
890
25
825
6) CONSTANT FLOW OPERATION
Whentheconstantowoperationinenabled(on), the unit speeds up or slows down depending on the
variationsoftheresistancescausedbylonglengthductingorexternalwindyconditions.
Theconstantowoperationcanbesetinthefollowingway:
-presstheMENUbuttonuntilthe“c”(c) letterisdisplayed.
-pressthebuttons+or-toenableordisable,asfollows:
CONSTANT FLOW (c)
Setting Value Displayed
Off(default)
of
On
on
7) INSTALLATION TYPE
Basedontheselectedinstallationtype,theunitscalesitsspeed(minimum,intermediateandmaximum)to
obtaintheselectedairowrates.
“Throughwall”installation:unitistypicallymountedonanexternalwallorwindowanddischargedirectto
the outside.
“Inroom”installation:unitistypicallymountedontheceilingorinternalwallwhichareductedtotheoutside.
NOTE:theunitrunsatahigherspeedwhen“Inroom”installationisselected.