MANUAL INSTALLATION BF 100MX

15
BF100MXisadecentralisedmechanicalventilationunitdesignedtoensureairextractioninsmall/medium-
sizedrooms.Suitableforairdischargeinthepresenceoflongductedsystem.Wall,ceilingorwindow
installation(fig.1).
INTRODUCTION
TECHNICAL SPECIFICATIONS
• Material:highquality,impactandUV-resistantABScolourRAL9010.
• Design front cover removable for cleaning without the use of tools.
• Highefciencymixedowimpellertooptimisequietnessandefciency.
• SinglephaseECBrushlessmotorforenergysaving,withintegralthermalprotection.
• Motormountedonhighqualityballbearings.
• 7segmentsLEDdisplayandbuttonsforconguration.
• Minimumspeedforcontinuousrunning,intermediatespeedandmaximumspeedselectableasindicated
in§3,4and5.
• OptiontoboostfromtricklethroughLSconnection.
• Installationtypeselectionavailable(throughwallorducted).
• Smarthumiditycontrolandintelligentrun-ontimer.
• Constantvolumemode.
• Suitableforcontinuousrunning.
• The fan is double insulated: no earth connection is required.
• IPX4degreeofprotection.
• Powersupply220-240V~50Hz
equipment operation.
•Installtheproductsothattheimpellerisnotaccessiblefromtheairoutletsideas
veriedbycontact withtheTestFinger(testprobe“B”ofthenorm EN61032)in
compliancewiththecurrentsafetyregulations.
•Windowinstallation
Incaseofwindowinstallationitisnecessarytousetheappropriatewindowkit,
which is not included.
Attention:donotmounttheproductonthewindowwithoutthiskit.
Additional safety feature:whenthedesignfrontcoverisremoved,theimpellerstopsturningtocongure
theunit.Toaidthesettingthisfeatureisdisabledfortherst60minutesofoperation.
Uponpower-up,theunitrunsattheminimumcontinuousspeed(§3).
Ifhumidistatortimerisactivated,theunitrunsattheintermediatespeed(§4).
Iftheexternalswitchisactivated,theunitrunsatthemaximumspeed(§5).
Aftertheexternalswitchisoff,theunitcontinuestorunatthemaximumspeedforthepre-setperiodoftime,
then it returns to the selected minimum speed (or to the intermediate speed in case humidistat or run-on
timer operation is on).
NOTE:therun-ontimerfunctionisactivatedonlyiftheexternalswitchhasbeenonforatleast3minutes.
OPERATION
Theunitisequippedwitha7segmentLEDdisplay,visiblebyremovingthedesignfrontcover,andthat
illuminatesbypressinganybutton.
888
Menu