Manual PDK65

s
PEPE
PEPE
N
NN
L
-
-
+
VARNING
Vid fel anlita
elektriker
Fassäkring max 10 A
Denfasta elinstallationen
är delvis spänningsatt.
I
C
C
C
PE
N
L
12 VDC
L
L
PDK65
s
PEPE
PEPE
N
NN
L
-
-
+
Warning
High Voltage!
Maintenance is only allowed
by authorized personnel
No Fuseincluded: ExternalFusemax 10A
WARNING!
The installation of this product requires working
with high-voltage and may only be carried out
by a qualied electrician.
The power must be isolated prior to installation
and opening of the product.
This product may only be installed using phase circuit
breakers of the following types:
- Automatic circuit breaker 10B.
- Automatic circuit breaker 10C.
- Safety fuse 10A gG.
Contactors may not be connected to the power supply
without the jumper “Direct/Ext.Cont” being set to “Ext.
Cont”.
See detailed description in the manual prior to installation.
Only use this product for its intended purpose (see man-
ual).
The product should be checked for any damage immedi-
ately after unpacking.
Should any damage to the product be discovered, do not
proceed with installation under any circumstances what-
soever.
Cabling may not be laid under the circuit board under any
circumstances.
If for any reason there is suspicion that safe use of the product
cannot be guaranteed, power to the product must immediately
be switched off. It must be ensured that switching on power to
the product cannot be activated unintentionally.
The PDK65 has shared mounting, which means that the detec-
tor can easily be connected with a low voltage cable and posi-
tioned for optimum detection.
The detector is a passive infrared detector with high sensitivity
(passive IR sensor) for presence detection. It has interchangea-
ble lenses which allows you to adapt the detection range.
The power supply is special-
ly adapted for shared mounting
and intended to power the pres-
ence detector. The system is in-
tended for the control of light-
ing xtures on the output side
in communal laundries, ofc-
es, corridors, waste rooms and
bicycle storage rooms.
See technical specica-
tions for switching
power.
The power supply can generally replace the terminal box
housed in the existing junction point between phase in/out and
the power switch in which case it is not necessary to install an
extra power cable. This functions as power supply, output relay
and simple logic module all in one. An external switch for man-
ual on/off can be connected. The power supply also has a con-
nection for earth protection.
Introduction
PDK65 is a complete system with easy installation to control
presence detection in smaller premises.
PDK65 consists of:
Power supply
Presence detector
3 m cable between module and
detector.
Presence detector for 230 VAC - PDK65
(kit with power supply)
Installation instructions
Presence
detector
Power supply

Summary of content (4 pages)