OM Commercial Wall Panel Fans

1. DIAGRAM A Intake ONLY
To change the airflow direction remove link from terminal 1 in the
plug and connect into terminal 2.
2. DIAGRAM B EXTRACT ONLY
All models are pre wired in factory to extract only. When the cable
supplied with the socket for test purposes is connected to a fused
spur or plug socket.
3. DIAGRAM C REVERSIBLE SPEED CONTROLLER
For the 9" and 12" models using the reversible variable
speed controller part no.
1. Electrical
220-240V AC.50HZ IP44
Temerature . Max 40˚C
Size 6" - RANGE - 45W
Size 9" - RANGE - 80W
Size 12" - RANGE - 120W
THIS FAN SERIES IS DOUBLE INSULATED AND DOES NOT REQUIRE AN
EARTH. THE EARTH TERMINAL IS PROVIDED FOR SPECIAL
INSTALLATIONS ONLY.
NOTE
Do not install within a shower cubicle or anywhere else where there is a high
risk of the fan being sprayed with water.
Fan to be fitted a minimum 2.3 metres from the floor.
IMPORTANT
Switch off mains supply before making any electrical
connections. If in any doubt contact a qualified electrician.
The appliance is not intended for use by young children or infirm
persons without supervision.
Young children should be supervised to ensure that they do not
play with the appliance.
Precautions must be taken to avoid the back-flow of gases into
the room from the open flue of gas or other open-fire appliances
when mounted in outside windows or walls.
Warranty & Service
This product is guaranteed for 12 months and is covered by service or
replacement where applicable. Fans & Spares are happy to provide you with any
assistance you may require with all aspects of service enquiries.
Please call on 0121 322 0200.
www.fansandspares.co.uk
Fans & Spares Tel : 0121 322 0200 Fax : 0121 322 0201
72 Cheston Road, Birmingham, B7 5EJ