Handbook NOVA C 202204

11/22 | NOVA-C
Quick Selection
Air flow volume q
v
at different A-weighted sound power levels L
WA
NOTE: The working points were measured with open R1-NOVA damper.
Item
25 dB(A) 30 dB(A) 35 dB(A)
m³/h l/s m³/h l/s m³/h l/s
NOVA-C-1-225x75-V-SW 173 48 226 63 - -
NOVA-C-1-225x125-V-SW 277 77 368 102 - -
NOVA-C-1-225x175-V-SW 367 102 501 139 - -
NOVA-C-1-225x225-V-SW 448 124 624 173 - -
NOVA-C-1-325x75-V-SW 234 65 315 88 - -
NOVA-C-1-325x125-V-SW 370 103 509 141 - -
NOVA-C-1-325x175-V-SW 491 136 691 192 - -
NOVA-C-1-325x225-V-SW 590 164 856 238 - -
NOVA-C-1-325x325-V-SW 738 205 1133 315 - -
NOVA-C-1-425x75-V-SW 295 82 403 112 - -
NOVA-C-1-425x125-V-SW 456 127 645 179 - -
NOVA-C-1-425x175-V-SW 599 167 869 241 - -
NOVA-C-1-425x225-V-SW 715 199 1068 297 - -
NOVA-C-1-425x325-V-SW 873 243 1390 386 - -
NOVA-C-1-525x75-V-SW 345 96 483 134 - -
NOVA-C-1-525x125-V-SW 544 151 779 216 - -
NOVA-C-1-525x175-V-SW 696 193 1034 287 - -
NOVA-C-1-525x225-V-SW 828 230 1269 353 - -
NOVA-C-1-525x325-V-SW 1002 278 1641 456 - -
NOVA-C-1-625x75-V-SW 397 110 564 157 - -
NOVA-C-1-625x125-V-SW 609 169 894 248 - -
NOVA-C-1-625x175-V-SW 792 220 1197 332 - -
NOVA-C-1-625x225-V-SW 939 261 1466 407 - -
NOVA-C-1-625x325-V-SW 1108 308 1861 517 - -
NOVA-C-1-825x75-V-SW 491 136 716 199 - -
NOVA-C-1-825x125-V-SW 749 208 1132 315 - -
NOVA-C-1-825x175-V-SW 962 267 1501 417 - -
NOVA-C-1-825x225-V-SW 1126 313 1821 506 - -
NOVA-C-1-825x325-V-SW 1301 361 2278 633 - -
NOVA-C-1-225x75-R1-V-SW 107 30 142 39 180 50
NOVA-C-1-225x125-R1-V-SW 163 45 222 62 287 80
NOVA-C-1-225x175-R1-V-SW 206 57 287 80 379 105
NOVA-C-1-225x225-R1-V-SW 243 68 346 96 464 129
NOVA-C-1-325x75-R1-V-SW 137 38 189 52 245 68
NOVA-C-1-325x125-R1-V-SW 206 57 289 80 384 107