9
EN
Application area
Cat is a range of compact and quiet fan
heaters for stationary use. It is ideally suited
for small stockrooms, in a garage, workshop
or shop. Protection class: IP44.
Assembly
The Cat fan heater is mounted on a wall and
has a fixed tilt angle, 10° downwards, which
gives balanced and good heat distribution
• Note that the minimum distances as
indicated in the figure on page 2 must be
maintained.
• The unit must be installed with the
connection area to the left, as seen from
the front.
• Mark out and drill the holes for the screws
as set out in the diagram on page 2.
• Screw in the screws for the keyholes so that
approximately 10 mm remains.
• Hang-up the unit and tighten the screws.
• Screw in the last screw.
Electrical Installation
The installation should be permanent
and carried out by a qualified technician
according to applicable directives. The
installation should be preceded by a fully
isolating switch with at least a 3 mm gap and
preferably fitted with a status lamp.
The Cat fan heater is intended for permanent
installation. The knockouts at the rear of the
unit are used to connect accessories. C3 can
also be connected to single phase (230V~).
On the back of the appliance there are knock-
outs. Cable-glands used must guarantee the
protection class requirements!
The heaters can be connected for either
230V3~ and 400V3N~. Note! Other models
cannot be connected for single phase.
Function
It is possible that the temperature limiter
may have tripped during transport, if the unit
does not function the first time it’s switched
on. Rectify as set out in the description under
“Overheating”. (Fig. 1)
Overheating
If the unit overheats the integrated
temperature limiter will trip. Reset the
temperature limiter after the unit has cooled
and the fault rectified. (Fig. 1)
NOTE! All work inside the unit’s connection
area should be carried out by an authorized
Position of the output selector,
see Technical data.
Installation and operating instructions
General Instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid if the product is used
in the manner intended and in accordance
with the instructions.
Control
When using this product as a local space
heater according to Ecodesign Regulation
(EU) 2015/1188, it must be supplemented
with one of the following approved controls.
• TAP16R, electronic thermostat that
includes:
- Electronic room temperature control plus
week timer
- Room temperature control with open
window detection
- Adaptive start control
The product can be controlled in a different
way, e.g. by an overall control system (BMS),
but in that case the responsibility lies with
the installer to ensure that the control system
is programmed to make the installation meet
the requirements of Ecodesign Regulation
(EU) 2015/1188.
Start-up
When the unit is used for the first time or
after a long period of disuse, smoke or odour
may result from dust or dirt that has collected
on the element. This is completely normal
and disappears after a short time.
Switch for the external thermostat:
control of heat only or both
heating and fan.