Manual IH

IH
7
EN
Installation and operating instructions
General Instructions
Read these instructions carefully prior to
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid should the product
be used in the manner intended and in
accordance with the instructions.
Application
The infrared heater IH is powerful with a
high filament temperature of 2200 °C and
is the perfect choice for exposed outdoor
environments where design is important. IH
is available in two different designs. IHW gives
a comfortable heat in the occupied zone from
close range and also wider heat distribution.
IHF has more direct heat distribution and is
designed to be installed higher up.
Protection class: IP44.
Positioning
The heaters must be placed so that they
cover the area to be heated, see fig. 1. The
normal mounting height is 2–3 metres above
the ground/floor. A rule of thumb for infrared
heaters is that 600–800 W/m² increases the
experienced temperature by about 10 °C. The
output demand can be reduced if the area to
be heated is protected. If the area only has a
roof, at least 800 W/m² should be installed.
600 W/m² is sufficient if the area has three
walls. For enclosed areas, the output demand
must be calculated. Optimum comfort is
achieved if the heat is distributed from at
least two directions. IHW provides wide heat
distribution (60°), recommended installation
height 1.8 – 2.5 m. IHF provides directed heat
distribution (40°), recommended installation
height 2.3 – 3.5 m.
Start-up
When the unit is used for the first time or
after a long period of non-use, smoke or an
odour may result from dust or dirt which has
collected on the element. This is completely
normal and disappears after a short time.
Mounting
IH is installed horizontally on walls with
supplied bracket. The heater can be angled
up to 45°. The heater can also be mounted
on e.g. a parasol or a post, a suitable U-bolt
(not included) is used for this together with
the supplied console. For ceiling installation
use ceiling bracket IHE (accessory). For other
mounting alternatives, see accessories.
For minimum distance, see diagrams on
introductory pages.
1. Secure the bracket on the wall with at least
2 screws. If the keyhole slots are used, an
addition screw is needed to fix the bracket.
See the introduction pages.
2. Remove the screws fixed to the unit's back
on delivery.
3. Hook the unit on the bracket.
4. Lock in position with the screws.
Connection
IH is equipped with a 0.9 metre cord with plug
for connection to an earthed outlet socket.
The connection cord must not rest against the
unit as the surface becomes hot or can be hit
by thermal radiation. Contact an electrician
if the cord needs to be changed. Note that
due to the high temperatures in the heater,
a cord of the type H05 RN-F 3G1 mm² or the
like should be used. As the halogen lamp has
a high starting current the wall socket should
be fuse protected by a slow burn fuse. In the
event of uncertainty contact an electrician.