User's Manual

Table Of Contents
GlobalTrak ™ GT Lite Operation and Maintenance Manual
Sensor Configuration Message
The sensor configuration message allows the user to configure the sensor parameters and
thresholds for the GT Lite. Below are the configurable parameters.
Parameter Description
Optic Threshold Threshold for optic events
Shock Threshold Threshold for shock events
High Temp Threshold High threshold for temperature events
Low Temp Threshold Low threshold for temperature events
Battery Threshold Low battery threshold
Analog 1-4 Low
Threshold
Low Thresholds for ZigBee analog sensors 1-4
Analog 1-4 High
Threshold
High Thresholds for ZigBee analog sensors 1-4
In Motion Debounce Debounce time for in motion events
Stationary Debounce Debounce time for stationary events
Door Enable Door Sensor enable/disable
Mount Enable Mount Sensor enable/disable
External Power Enable External Power Sensor enable/disable
Motion Enable Motion Sensor enable/disable
Digital 2-5 Enable Enable/Disables for ZigBee digital sensors 2-5
Speed and Direction
Enable
Speed and Direction enable /disable
Power Configuration Message
The power configuration message allows the user to configure power parameters and for the
GT Lite. Below are the configurable parameters.
Parameter Description
Stationary Transmit Transmit interval used while the device is stationary
Powered Transmit Transmit interval used while the device is powered
In Motion Transmit Transmit interval used while the device is in motion
SMS Enable SMS enable/disable
GPRS Enable GPRS enable/disable
GPS Enable GPS Receiver enable/disable
Sensor Suite Enable Sensor suite enable/disable
GPS Hot Fix Timeout Time allotted for GPS hot fix
Prepared: R. Straz Date: July 25, 2007 Page 40 of