User's Manual

6
PIN NO. WIRE GAUGE DESCRIPTION
1 10 AWG M1 OUT 12V (12V FOR M1 EXTEND)
2 10 AWG M1 IN 12V (12V FOR M1 RETRACT)
3 10 AWG M2 OUT 12V (12V FOR M2 EXTEND)
4 10 AWG M2 IN 12V (12V FOR M2 RETRACT)
5 10 AWG M3 OUT 12V (12V FOR M3 EXTEND)
6 10 AWG M3 IN 12V (12V FOR M3 RETRACT)
7 10 AWG M4 OUT 12V (12V FOR M4 EXTEND)
8 10 AWG M4 IN 12V (12V FOR M4 RETRACT)
9 10 AWG M5 OUT 12V (12V FOR M5 EXTEND)
10 10 AWG M5 IN 12V (12V FOR M5 RETRACT)
11 10 AWG M6 OUT 12V (12V FOR M6 EXTEND)
12 10 AWG M6 IN 12V (12V FOR M6 RETRACT)
13 10 AWG M7 OUT 12V (12V FOR M7 EXTEND)
14 10 AWG M7 IN 12 V (12V FOR M7 RETRACT)
15 16 AWG TRAVEL LOCK 12V IN
16 14 AWG LIGHT GROUP 12V IN
17 14 AWG LIGHT GROUP GND
18 14 AWG LIGHT GROUP 12V OUT
19 14 AWG LIGHT GROUP SWITCH INPUT 12V
20 10 AWG MOTOR 7 GND OUT (M7 IN)
WIRING
The wiring diagram depicts all the wiring connections required for proper operation of the unit.
The TX (transmit) and RX (receive) connections at each device are crossed (crossover cable).
BODY CONTROL MODULE (BCM) CONNECTIONS
PIN NO. WIRE GAUGE DESCRIPTION
21 10 AWG MOTOR 7 12V OUT 30 AMP (M7 OUT)
22 10 AWG MOTOR 6 GND OUT (M6 IN)
23 10 AWG MOTOR 6 12V OUT 30 AMP (M6 OUT)
24 10 AWG MOTOR 5 GND OUT (M5 IN)
25 10 AWG MOTOR 5 12V OUT 30 AMP (M5 OUT)
26 10 AWG MOTOR 4 GND OUT (M4 IN)
27 10 AWG MOTOR 4 12V OUT 30 AMP (M4 OUT)
28 10 AWG MOTOR 3 GND OUT (M3 IN)
29 10 AWG MOTOR 3 12V OUT 30 AMP (M3 OUT)
30 10 AWG MOTOR 2 GND OUT (M2 IN)
31 10AWG MOTOR 2 12V OUT 30 AMP (M2 OUT)
32 10 AWG MOTOR 1 GND OUT (M1 IN)
33 10 AWG MOTOR 1 12V OUT 30 AMP (M1 OUT)
34 10 AWG CHASSIS GND (IN)
35 10 AWG MOTOR FEED 12V (IN)
36 10 AWG BCM 12V (IN)
37 24 AWG 12V OUT (CONNECT TO DC)
38 24 AWG TX (CONNECT TO DC RX)
39 24 AWG RX (CONNECT TO DC TX)
40 24 AWG GND OUT (CONNECT TO DC)