User's Manual

JRVCS105
10
TROUBLESHOOTING
Symptom Solution
Display Commander (DC)
will not turn ON or the touch
screen will not function
Press Reset Button on BCM
Check main fuse in Distribution Panel.
Check 12V+ on wire to DC (RED wire).
Check Ground wire to DC.
No power to the Body
Control Module (BCM)
Try cycling power at Distribution Panel.
Check if the Red power LED is off.
Check the fuse in the Distribution Panel.
Check 12V+ on wire at pin 35. Check Ground wire at pin 33.
Ensure Pin 7 is NOT grounded
DC screen flashing on and
off after installation
Cycle power to the BCM and DC
Ensure the wires to the BCM and DC are connected and there is 12V
Ensure the wires to the BCM and DC are not damaged or pinched
Ensure the Battery is charged
Electric Motors do not move Check 12V+ at Pin 34. Ensure the relay activates*.
Travel Lock on Ensure 12V+ is removed from Pin 15.
*Relay not activating Replace the 1505 relay with one from an unused circuit by gently pulling
it off the board, or install an new one.
If an issue is unable to be resolved using the above methods, contact ASA Electronics
Technical Support at 1-877-845-8750 or email them at info@asaelectronics.com