User's Manual
User Manual: Field Transmitter
PCU_User_Guide_1.3.0 3 © 2019 Syscor Controls & Automation Inc.
b. Impedance 50 Ω
Installation
2.1 Location Planning
PCU location will depend on availability of mounting locations and presence of possible interference for
wireless network transmission. Sensor location will be dictated largely by the needs of the system being
monitored. A variety of options are available for mounting both the sensor and PCU together or separately as
needed.
Range of permitted environmental conditions:
• Indoor / outdoor
• Pollution degree 4
• Water submersion to a depth of 1m
• -40 to +60 Celsius ambient temperature
2.1.1 Sensor and PCU Placement Considerations
Sensors may also be mounted
directly to the sensor ports on the
bottom of the PCU rather than
remote mounted.
Sensors are provided with cable
permitting remote mounting.
Combined cable length cannot
exceed 10 meters or 33 ft.
Figure 2: PCU with body-mounted
sensors
Figure 1: PCU with cable-mounted
sensors