1.4 Mechanical Drawings
These drawings in Figure 1.1 show the module with the RPSMA connector for use with
an external antenna, and the keep put area for the F-antenna. There should be no
copper, components, or fasteners on any layer of the host board beneath the keep out
area.
Figure 1.1 Mechanical drawings of the RF200APD1 and RF200APF1 Modules
1.5 Board Mounting Configurations
The RF200PD1 and RF200PF1 modules are designed to mount into a receptacle
(socket) on the host board. Picture 1.1 shows an RF200PD1 module plugged in to a
host board. The receptacle sockets are on standard 2mm centers. Suggested
receptacles to be used on the host are:
Thru-hole receptacle Samtec MMS-112-01-L-SV
Surface mount receptacle Samtec MMS-112-02-L-SV
It is recommended that the mounting holes provided in the module on either side of the
SMA connector be used with supporting mounting hardware to hard mount the module