Installation Sheet

Single Handle Pressure-Balancing Mixing Valve for Shower or Tub/Shower Application
INSTALLATION, OPERATION & SERVICE INSTRUCTIONS
NOTE: 2-3/8 (60mm) min.
3” (76mm) max. 2-5/16 (59mm)
fixed dim. metal stall.
Valve inlets and outlets are
1/2 (13mm) IPS connections.
5 5/8”
143mm
9 1/2”
240mm
approx.
24”
610mm
Symmons valves, shower heads
and hand sprays comply to all
known standards, codes and
specifications: CSA B-125, ANSI
A-112.18.1M, ASSE 1016, EPA ‘92
etc. Symmons shower heads and
hand sprays are equipped with a
2.5 gpm (9.5 L/min) water and
energy saving flow restrictor.
This instruction sheet shows rough-in
dimensions for Models 4-500(X), 1-100(X)
and 1-215-X. See separate drawings
enclosed with numbered models for appli-
cable rough-in dimensions.
Tools required for installation of this prod-
uct are: Phillips screw driver, tubing cutter,
teflon tape, soldering equipment, adjust-
able wrench and channel-lock pliers.
Installation of Shower System
Model 1-100(X) (Figure 2)
Install HOT on left and COLD on right
according to valve markings.
1. Install piping and fittings with valve
body as shown in Figure 2 or 3.
IMPORTANT: Valve rough-in is 23/8”
(60mm) min. — 3” (76mm) max. from
CENTERLINE OF SUPPLIES TO FACE
OF FINISH WALL. Install so that surface
indicated on plaster shield on valve
is flush with finish wall as shown in
Figure 1.
2. When finishing tile wall REMOVE
(pull off; don’t turn) ENTIRE PROTEC-
TIVE PLASTER SHIELD and FILL AREA
AROUND VALVE BODY WITH GROUT
OR PLASTER. DO NOT PLASTER OVER
SC-2 CAP OR SERVICE STOPS IF SO
EQUIPPED.
3. Turn on hot and cold supplies, valve
will not operate unless both hot and
cold water are turned on.
4. This valve is equipped with a limit
stop screw to be used to limit
valve handle from being turned
to excessively hot water discharge
temperatures. To adjust, remove
dome cover, place handle (RC-14)
on stem, open valve to maximum
desired temperature and turn
in limit stop screw until it seats.
WARNING: Failure to adjust the
limit stop screw properly may
result in serious scalding.
finish wall face
4
1
4
"- 4 "
108mm
114mm
1
2
2
3" 76mm max.
60mm min.
3
8
"
supplies
C
L
plaster shield
FIGURE 2
Model 1-100(X) Shower System
FIGURE 1
All floor to center dimensions optional. Concealed piping and fittings not furnished by manufacturer.
Safetymix
®

Summary of content (4 pages)