Install Instructions
MAINTENANCE
FILTER CLEANING INSTRUCTIONS
This faucet is provided with one stainless steel lter preventing foreign particles to enter
the lines. It is recommended to clean the lter every six (6) months. If the water flow has
decreased, this can be because the lter is clogged. The lter can be cleaned as follows:
. Shut-o the water shut o valve (angle valve).
. Remove the lter located between the solenoid valve housing and the inlet adapter \
shut o valve.
. Wash the lter under running water.
. Reassemble the parts.
. Make sure that there is no water leakage.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like.
Use of any prohibited cleaning or maintenance products or substances could damage the
surface of the faucet. For surface cleaning of faucet use ONLY soap and water, then wipe dry
with clean cloth or towel. When cleaning bathroom tile, the faucets should be protected
from any splattering of harsh cleansers.
SOLENOID VALVE SERVICING
The solenoid valve diaphragm requires periodical cleaning every six (6) months. Remove
the diaphragm from the solenoid valve and examine it for dirt. in case it is dirty or clogged,
wash it under running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic
solenoid valves.
SF Seals and screws
SF Solenoid valve kit (single)
SF Solenoid housing kit (single)
SF Battery box
SF V switching transformer
USDP ” DECK PLATE
USDP 8” DECK PLATE
SPARE PARTS LIST
SF250
Seals and Screws
SF259
9V switching transformer
SF255
Solenoid housing kit
SF253
Solenoid valve kit
SF258
Battery box