Install Instructions
SETTINGS ADJUSTMENT
FOR SB:
a. The battery box can be secured to
the wall underneath the sink
using the screw.
b. Connect the waterproof connector
coming from the electronic unit to
the battery box.
FROM THE ELECTRONIC UNIT TO THE BATTERY BOX
FOR SE:
a. Connect the waterproof connector
coming from the electronic unit to
the transformer.
FROM THE ELECTRONIC UNIT TO THE TRANSFORMER
b. Plug the transformer into the elec-
tricity socket.
IMPORTANT: Wait seconds before operating
the system.
SECONDS
If the range is unsatisfactory, refer to the section titled ”Settings
adjustment”.
INSTALLATION
DETECTION
RANGE
DELAY IN TIME
SECURITY TIME
COMFORT FLUSH
DELAY OUT TIME
TEMPORARY OFF
FUNCTION
RESET
HYGIENE FLUSH
Adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut o the water supply. In order to adjust the sensor with the remote control, hold the
remote control straight in front of the sensor in a distance of about 6-8” (cm). Choose
the function you want to adjust by pressing once on one of the function buttons. Aer
pressing once on a specic function button, a quick flashing of the LED at the front of the
sensor will occur. At this stage, you can change the setting by pressing the (+) or the (-)
buttons, every push will increase or decrease one level. Aer nishing the adjustment, turn
the water supply back on.
DETECTION RANGE: Only if necessary, use the remote control to adjust the
sensor range as follows:
Press the RANGE button. Wait until a quick flashing of the LED in the sensor
eye is perceived. Then, press + to increase the one level and – to reduce it
every push will increase or decrease one level.
NOTE: Once you have changed the detection range with the remote control, this
distance will be remembered by the sensor, even if the power source is disconnected.