S6960B/E SENSOR FAUCET E L E C T R O N I C L A VAT O R Y F A U C E T 1 I NSTA L LAT ION AND MAINT ENA NCE GUIDE
INDEX TECHNICAL DATA 1 TECHNICAL DATA 2 PACK CONTENTS 3 PRE-INSTALLATION INFO 4-6 INSTALLATION 7-8 SETTINGS ADJUSTMENT 9 BATTERY REPLACEMENT 10 MAINTENANCE Filters cleaning instructions Care and cleaning of chrome and special finishes Optional: Cover Plate Solenoid valve servicing 11 SPARE PARTS LIST 12 LIMITED WARRANTY 13 TROUBLESHOOTING The information in this document reflects products at the date of printing.
PRE-INSTALLATION INFO PACK CONTENTS Familiarize yourself with the part names and confirm that the parts are included. CHECK CONTENTS Separate all parts from the packaging and check each part with the “Pack contents” section. Pay attention to the different models variations. Make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not attempt to install your electronic faucet until you obtain the missing parts.
INSTALLATION INSTALLATION STEP 1 - REMOVE ALL MOUNTING HARDWARE STEP 3 – CONNECTING THE WATER SUPPLY Shut off water supply and remove the hexagonal nut, the disk and the gasket. Do not remove the o-ring from the base of the faucet. 1 Fit the flexible pipe coming from the faucet to the solenoid valve housing.
INSTALLATION SETTINGS ADJUSTMENT FOR S6960B: a. The battery box can be secured to the wall underneath the sink using the screw. b. Connect the waterproof connector coming from the electronic unit to the battery box. 3 FROM THE ELECTRONIC UNIT TO THE BATTERY BOX FROM THE ELECTRONIC UNIT TO THE TRANSFORMER DELAY OUT TIME DELAY IN TIME TEMPORARY OFF FUNCTION SECURITY TIME RESET COMFORT FLUSH HYGIENE FLUSH FOR S6960E: a.
SETTINGS ADJUSTMENT DELAY IN TIME: If required, the delay in time can also be modified as follows: Press the IN button. Wait until a quick flashing of the LED in the sensor eye is perceived. Then, press + to increase the delay in time and – to reduce it. DELAY OUT TIME: This button allows modifying the flushing start time after the user moves away from the product. A delay out time close to 0 will save more water. An increased delay out time will make the user experience more comfortable.
MAINTENANCE SPARE PARTS LIST FILTER CLEANING INSTRUCTIONS This faucet is provided with one stainless steel filter preventing foreign particles to enter the lines. It is recommended to clean the filter every six (6) months. If the water flow has decreased, this can be because the filter is clogged. The filter can be cleaned as follows: 1. Shut-off the water shut off valve (angle valve). 2. Remove the filter located between the solenoid valve housing and the inlet adapter \ shut off valve. 3.
LIMITED WARRANTY TROUBLESHOOTING Ensure all connections have been made before starting troubleshooting. All parts and finishes of the Symmons products are warranted to the original consumer purchaser to be free from manufacturing defects in material and workmanship for 5 years Non-Residential or Commercial Applications.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184-3804 1-800-796-6667 02.