Full Product Manual
BATTERY REPLACEMENT
IMPORTANT: Spent batteries should not be disposed of with normal household
waste. Contact your local authority for information on waste disposal and recycling.
SF Seals and screws
SF Sensor kit (single)
SF Sensor kit ( pack)
SF Solenoid valve kit (single)
SF Solenoid valve kit ( pack)
SF Solenoid housing kit (single)
SF Solenoid housing kit (8 pack)
SF Insert kit
SF Battery box
SF V switching transformer
SPARE PARTS LIST
MAINTENANCE
FILTER CLEANING INSTRUCTIONS
This faucet is provided with one stainless steel lter preventing foreign particles to enter
the lines. It is recommended to clean the lter every six (6) months. If the water flow has
decreased, this can be because the lter is clogged. The lter can be cleaned as follows:
. Shut-o the water shut o valve (angle valve).
. Remove the lter located between the solenoid valve housing and the inlet adapter \
shut o valve.
. Wash the lter under running water.
. Reassemble the parts.
. Make sure that there is no water leakage.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like.
Use of any prohibited cleaning or maintenance products or substances could damage the
surface of the faucet. For surface cleaning of faucet use ONLY soap and water, then wipe dry
with clean cloth or towel. When cleaning bathroom tile, the faucets should be protected
from any splattering of harsh cleansers.
SOLENOID VALVE SERVICING
The solenoid valve diaphragm requires periodical cleaning every six (6) months. Remove
the diaphragm from the solenoid valve and examine it for dirt. in case it is dirty or clogged,
wash it under running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic
solenoid valves.
BATTERY MODELS ONLY
When the battery weakens, the LED indicator light will blink at a constant rate when the user’s hands are
within the sensor range. The battery must be replaced within two weeks.
TO REPLACE THE BATTERY:
FOR SB:
EN .Remove the old batteriesEN .Carefully open the battery
box
EN . Unscrew the holding screw
EN . Close the box
EN . Replace the used batteries
with a new X .V batteries (Lithium
battery is recommended).
New Battery
Old Battery