Installation Guide
Page 2
 Installation Instructions
5)  Remove protective shield
If protective shield was attached 
in  Step 3 then remove shield 
snap tted over the end of valve 
spindle once valve is securely 
installed and wall nish work 
has been completed.
6)  Adjust valve packing nut
Reference gure 3 below
 ■ Turn hot & cold supplies on.
Valve will not operate unless 
both hot and cold water supply 
pressures are turned on. 
 ■ Place handle over end of control 
spindle stem.
 ■ Adjust packing nut for positive 
frictional resistance as handle 
is rotated from shuto position 
across adjustment range.
 Rough-in Installation
Control valve assembly, piping 
and fittings (Note: Illustrations below 
show valve model without stops)
Reference as required:  Page
Visual guide ....................................1
Dimensions illustration ................4
1)  Determine wall thickness
 ■  
Determine type of wall and wall 
thickness where valve will be 
mounted.
 ■ Consider whether to use mounting 
plate by reviewing gure 2 below.
 ■ Skip ahead to Step 3 if mounting 
plate is not used.
2)  Attach valve mounting plate
Seat mounting plate against valve 
assembly as illustrated in gure 1.
3)  Attach protective shield
 ■ Reference gure 2 to determine 
whether shield is required.
 ■ Attach protective shield by snap 
tting over end of valve spindle.
4)  Install piping, fittings and 
control valve
Piping and ttings not supplied
 ■ Control Valve
Install through cutout hole in wall 
as specied in gure 2 below and 
dimension illustration on page 4. 
 ■ Showerhead (S on valve)
Pipe from outlet port on valve 
marked S to showerhead 
mounting arm location.
 ■ Hot & Cold Supply (H & C)
Pipe hot water supply to valve 
inlet marked H and cold water 
supply to valve inlet marked C.
 ■ Tub Spout (T on valve)
Pipe from outlet port on valve 
marked T to tub spout.
Important! Do not 
substitute Tub Spout with 
restrictive ttings such as
PEX, CPVC or outlet accessories such 
as a ledge spout, hose and spray that 
would subject the valve to excessive 
internal back pressure, otherwise  
operation will be compromised.
Figure 1 Mounting plate 
Figure 3 Valve adjustments 
Figure 2 Mounting valve
wall
Temp Limit
stop screw
packing nut
control
spindle
stem
wall cutout hole size
3-1/2" (89 mm) min
 4" (101 mm) max
Finished wall must be
ush with back side of 
protective shield surface
nished wall
Dry wall, plaster or other type wall
 1/2" (13 mm) or greater
Protective shield
"snap on-off" 
(required when
 mounting plate
 is not used)
2-3/8" 
±
 1/2"
(60 mm 
±
13 mm)
pipe centerline 
to nished wall
 wall cutout hole size
3-1/2" (95 mm) min
 4" (101 mm) max
nished
 wall
Ensure valve’s
mounting plate
is ush against
inner wall
Walls for using T-177 mounting plate
 Fiberglass or acrylic walls (required)
 Plaster or other type walls (optional)
 1/16" (2 mm) min  1/2" (13 mm) max
p/n T-176
p/n T-177
Protective shield
When mounting plate is used, 
then shield is optional for 
protecting end of valve during 
installation.  
"snap on-off"