Installation Guide

MaxLine
®
Model Numbers Feature Highlights
8210CK
Thermostatic Mixing Valve
Operation & Maintenance Manual
8210CK Thermostatic Mixing Valve
Flowrates
Note: Append appropriate sux to model number.
Options/Modifications
B Wall cabinet in white enamel nish
including wall mounting bracket
D 3/8" compression tting to allow water
bypass for hot and cold supply faucet
NI Rough Nickel nish
T Stainless steel cabinet in place of
standard white cabinet
3/8" compression connections
Integral checks
Stainless steel strainers for protection against
suspended particles in supply lines
Thermal cartridge
Vandal resistant
Minimum ow rate 0.25 gpm (0.95L/min)
Inlet water temperature:
HOT inlet range 120°F - 180°F (48.9°C - 82.2°C)
COLD inlet range 39°F - 80°F (3.9°C - 26.7°C)
Temperature control range:
59°F - 115°F (15°C - 46°C)
Minimum supply pressure: 20 psi (138 kPa)
Maximum supply pressure: 125 psi (862 kPa)
Inlet to outlet temperature dierential: 10°F (5.55°C)
*According to US Senate bill S.3874, the term "lead free" is
dened as follows: "not more than a weighted average of 0.25
percent lead when used with respect to the wetted surfaces of
pipes, pipe ttings, plumbing ttings, and xtures."
Compliance
-ASME A112.18.1/CSA B125.1
-ASSE 1017/CSA B125.3
-ASSE 1070/CSA B125.3
-NSF/ANSI 372
-CSA B125.3
Table 1: Flow Rate - gpm (L/min)
Valve Model
Size
Connection
Min. Flow
Rate
Pressure Dierential - psi (kPa)
5 psi
(34 kPa)
10 psi
(69 kPa)
20 psi
(138 kPa)
25 psi
(172 kPa)
30 psi
(207 kPa)
45 psi
(310 kPa)
8210CK
3/8"
(10 mm)
0.25 gpm
(0.95 L/min)
1.32 gpm
(5.0 L/min)
2.06 gpm
(7.8 L/min)
2.74 gpm
(10.4 L/min)
3.11 gpm
(11.8 L/min)
3.38 gpm
(12.8 L/min)
4.22 gpm
(16.0 L/min)
Limited Lifetime - to the original end
purchaser in consumer/residential
installations.
10 Years - for commercial/industrial
installations. Refer to
www.symmons.com/warranty for
complete warranty information.
Warranty

Summary of content (6 pages)