Installation Guide

3
Installation
1) Reference rough-in dimension for
shower application with diverter
for proper installation of diverter
valve.
5) Sweat 1/2" copper tubing from
inlet port on diverter valve
to water source. Sweat 1/2"
copper tubing from outlet ports
to desired accessories.
Important: Do not plug
outlet ports. Do not use
diverter as shut-off valve.
2) Shut-off water supplies.
4) Secure stringer mounts on diverter
valve (E) to wood blocking for
support.
E
6) Turn on water supplies to ush
plumbing lines free of debris
.
Check for leaks.
!
E
3) Position diverter valve (E) so port
marked IN is facing down.
3
2
Optional: Apply plumber tape to
male IPS threads on the inlet and
outlet ports of diverter valve. Install
1/2"-14 NPT copper ttings to the
inlet and outlet ports. Connect
outlets to desired accessories.
Note: Securing stringer mounts is
necessary for applications where
PEX, or other non rigid tubing, is
used to install diverter valve.
Note: Diverter valve can be installed
in wall with shower valve or in an
adjoining wall to shower valve.
Important: Do not expose
diverter valve to heat for
longer than 2 minutes when
sweating in copper tubing.
Doing so may damage the
internal components of
the valve and will void the
product warranty.
Operation
1
POSITION 1
1) Cartridge is factory set to divert
to function 1.
2) Turn handle to position 2 to divert
to function 2.
2
POSITION 2