User Manual

Installation and Communication 2-7
5. Enter admin as the username and change as the password. These are the default settings. You cannot change the password
from the serial console. To change the password (or create a new user account) use the Web-based Administrator Console.
The host displays the Current Configuration menu:
Current Configuration:
Serial Number : redacted
MAC Address : redacted
1 -- DHCP : ON
2 -- IP Address : 192.168.127.254
3 -- IP Port : 3000
4 -- Network Mask : 255.255.255.0
5 -- Gateway : 192.168.1.1
6 -- DNS Host : 192.168.1.1
7 -- HTTP Server is : ON
8 -- HTTP Port is : 80
9 -- Telnet Server : Enabled
10 -- FTP Server : Enabled
11 -- Watchdog : Disabled
12 -- Trusted Hosts Only : OFF
13 -- Commit Change
14 -- Discard Change
15 -- Exit
16 -- Reboot
17 -- Show system log
18 -- Trace system log : OFF
Select the menu number to change the item value:
6. To change a setting, enter the menu number, press Enter, then enter the new configuration value. For example, to change
the IP address, enter 2 to select IP Address, then press Enter. Enter a new IP address value.
7. Enter 9, then press Enter, to apply the change.
Reading Tags
To read tags while communicating with the host serially, connect the XR400’s RS-422/485 interface to a serial port on the host
computer. Symbol provides an RS485-to-USB SeaLevel converter box and cable which connects the reader to the host's USB port for
serial communication.
To connect the reader to a host computer and read tags in real time, connect through TCP/IP and use a real-time application such as
TagVis. Refer to the TagVis Developer Guide, or the user guide provided with the application.