13.3 Environmental Conditions
Storage temperature:
-35C to +85C
Operating temperature:
-30C to +80C
Humidity*:
5% to 95% (non-condensing)
Temperature shock*:
-30C to +50C (85% R.H.) as per MIL-STD-
810G; Method 503.5 Procedure I-C (Multi-
cycle shocks)
* There will be NO environmental protection on the RA1202 radio module, as it is designed to be
fully enclosed within a host unit.
13.4 Labeling Requirements
3 different labels must be in the following 3 locations:
External to RA1202 radio module
External to host unit
External to host unit shipping box
They must include all applicable notices as per regulatory requirements of section 5.0 adhering
to the minimum text and label sizes defined therein.
Identify Symbol Technologies Inc RA1202 radio module and part number specific to the radio
configuration.