Reference Guide

Table Of Contents
7-3
Error Recovery and Troubleshooting
Troubleshooting
Table 7-2 lists some minor problems, causes, and actions to take. If you cannot resolve the
problem after checking this list, call the Symbol Support Center for assistance.
Startup Failure
Problems are most frequently start-up failures. If cold booting the terminal does not start the
application successfully, the application, the system software, or the system is
malfunctioning. If you can boot the system to Command Mode, try the following:
!
Use Program Loader to download a new version of the software to NVM. This
procedure is described in Chapter 3, Batch and Spectrum One Terminal Setup or
Chapter 4, Spectrum24 RF Terminal Setup. After downloading new software, warm
boot the terminal as described in Chapter 5, Operating the PDT 6800 Series.
!
Use Self Test to check whether system hardware is operational. The Self Test
procedure is described later in this chapter. After downloading new software, warm
boot the terminal as described in Chapter 5, Operating the PDT 6800 Series.
Boot Failure Messages
During a cold boot, the system briefly displays a status line for each driver as it loads, in the
format
0:Driver #.##
The line shows a status value, usually 0, followed by the name and version number of the
driver. If the system halts at one of these lines and displays a status value other than 0, the
displayed driver did not load properly.
Table 7-2. Troubleshooting the Terminal
Symptom Possible Cause Action
Display is blank. Battery pack is dead or
missing.
Replace or recharge battery
pack.
Terminal does not respond
when keys are pressed.
Application program was not
successfully downloaded.
Repeat downloading.
Time and date are incorrect. Real-time clock has
malfunctioned or needs
setting.
Set time and date. See your
application guide.