Reference Guide

Table Of Contents
F-10
PDT 6800 Series Product Reference Guide
xmit_i25_chkdgt Enable to transmit the check digit with the data. Disable to
transmit the data without check digit.
msi_chkdgt_scheme Select which algorithm to use when the number of check digits is
set to 2 check digits.
0 = Mod11/Mod10
1 = Mod10/Mod10
check_i25_chkdgt Select I 2 of 5 check digit type:
0 = Do not use check digit
1 = Use USC (Uniform Symbology Specification) check
digit
2 = Use OPCC (Optical Product Code Council) check digit
random_weight_chkdgt This parameter applies to both EAN-13 and UPC-A:
0 = disable random weight check digit
1 = use four digit method to calculate check digit
2 = use five digit method to calculate check digit
tri39_red_enabled Enable TriopticCode39 redundancy.
cvtEAN8_2_EAN13 Convert EAN-8 barcode type to EAN-13. When EAN Zero
Extend is enabled, this parameter gives you the option of label-
ing the extended symbol as either an EAN-13 bar code, or an
EAN-8 bar code. This affects Transmit Code ID Character and
DECODE_DATA message. When EAN Zero Extend is disabled,
this parameter has no effect on bar code data. Uses
conv_ean8to13_b from decoder parameters to enable EAN Zero
Extend.
cvtI25_2_EAN13 Convert I 2 of 5 barcode type to EAN-13. This parameter con-
verts a 14 character I 2 of 5 code into EAN-13. To accomplish