Appendix D
Specifications
Environment
The terminal’s operating conditions are listed in Tabl e D-1 .
Table D-1. Environmental Specifications
Note: Batteries lose power faster at extremely high and low temperatures.
The LCD operates slowly at temperatures below 0
o
C.
Condition Range
Operating Temperature -13°F to 122°F (-20°C to 50°C)
Storage Temperature -13°F to 140°F (-20°C to 60°C)
Humidity (Operating) 95% relative humidity, noncondensing
Altitude Up to 10,000 feet
Electrostatic Up to 15 KV discharge to all surfaces (terminal
power may go off)
Shock Withstands multiple 4-foot drops to concrete
without malfunction or loss of data