User's Manual

A - 2 MC18 Product Reference Guide
Data Capture Method Imager (SE4710) with red LED Illumination and LED dot aim pattern.
Imaging rate: 30 Frames per second, 1280p x 800p
Imager SafetyIEC/FDA Class 1 in accordance with IEC/EN 60825-1 & 21
CFR 1040.10 & 11 (Laser Notice No. 50)
User Environment
Operating Temperature 0° C to 40° C (32° F to 104° F)
Storage Temperature -20° C to 60° C (-4° F to 140° F)
Battery Charging Temperature 0° C to +40° C (32° F to 104° F) ambient temperature range.
Humidity 40° C (RH 10% - 95%) Non-condensing
Flammability UL94V1
Drop Specification Multiple 4 ft.(1.2 m) drops to tile linoleum over concrete across operating
temperature range
Sealing Liquid penetration per “A4T Casual Spill Test Spec” document number
71-98611-01. Applies ONLY with battery installed.
ESD ± 20k VDC air discharge
± 10k VDC contact discharge
Interface/ Communications
WLAN radio TI / 1273L - Wi-Fi IEEE® 802.11a/b/g/n with internal antenna
Operating Channels:
Channel 1 - 13 (2412 - 2472 MHz)
Actual operating frequencies depend on regulatory rules and certification
agency.
Authentication:
EAP-TTLS authentication with tunnel types CHAP, MSCHAP, MSCHAPv2,
PAP, MD5, EAP-TLS, PEAP-TLS authentication with tunnel types TLS,
MSCHAPv2, and GTC, LEAP, EAP-FAST authentication with tunnel types
TLS, MSCHAPv2, and GTCon, EAP-AKA , WAPI
Encryption: None, 128-bit AES, TKIP, WEP-128, WEP-40/65
Bluetooth Communications TI / 1273L - MS stack 2.1
USB USB 2.0 Client for Microsoft ActiveSync or Windows Mobile Device Center,
for service and maintenance
Regulatory
Electrical Safety Certified to UL/cUL 60950-1, IEC 60950-1 ; IEC 62471:2006/EN62471:2008
(LED Safety Report)
EMI/RFI North America: FCC Part 15 Subpart B
class B
Canada: ICES 003 Class B
EU: EN55022 Class B, EN 301 489-1, EN301 489-17, EN61000-4-3/-3-2/-3-3
Table A-1
Technical Specifications (Continued)
Item Description