User's Manual

10 EMG101 Gateway
2.5 Wall Mount Installation
To support wall mount installations, the EMG101 Gateway is fastened directly to a flat wall surface. The wall
should be of gypsum board, plaster, wood or concrete in composition.
To install the EMG101 Gateway to a wall surface:
1. Orient the EMG101 Gateway by either its width or length.
2. Mark the mounting surface at the target screw insertion points.
3. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall mounting screw and
stop when there is 1mm between the screw head and the wall.
4. If pre-drilling a hole, the recommended hole size is 2.8mm (0.11in.) if the screws are going directly into
the wall and 6mm (0.23in.) if wall anchors are being used.
5. If required, install and attach a security cable to the EMG101 Gateway lock port.
6. Attach the antennas to their correct connectors.
7. Place the large center opening of each of the mount slots over the screw heads.
8. Slide the EMG101 Gateway down along the mounting surface to hang the mount slots on the screw heads.
9. Cable the EMG101 Gateway using either the Power Injector solution or an approved line cord and power
supply.
For Symbol Power Injector installations:
a. Connect an RJ-45 CAT5 Ethernet cable between the network data supply (host) and the Power
Injector’s Data In connector.
b. Connect an RJ-45 CAT5 Ethernet cable between the Power Injector’s Data & Power Out connector
and the EMG101 Gateway.
CAUTION EMG101 must only be connected to PoE networks without any
connections to an outside plant power source.
NOTE If not using the Power Injector to power the EMG101 Gateway, the only
other approved power solution is the standard power supply (Part
Number PWRS-147376-01R). The standard power supply does not
converge data and power in one cable, and requires a separate data
Ethernet connection in addition to a power connection. This product is
intended to be supplied by a listed power adapter marked “Class 2” or
“L.P.S” (or “Limited Power Source”) and rated from 48Vdc, 0.38A
minimum.
CAUTION An EMG101 Gateway should be wall mounted to concrete or
plaster-wall-board (dry wall) only. Do not wall mount the EMG101
Gateway to combustible surfaces.
!
!